0) Server configuration
IP Address : (10) .(0) .(0) .(16)
IP address of this Ethernet interface.
Press ‘.’ between the parts of the IP address and finish
with enter.
Set Gateway IP Adress (N) N
N
If the PC and this Ethernet interface are connected
to the same LAN segment.
Y
If they are not on the same segment.
Gateway IP Adr (000).(000).(000).(000)
The gateway address should be the IP address of the
router connected to the same LAN segment as the
Ethernet interface you are configuring.
Netmask: Number of Bits for Host Part
(0=default) (08)
8
bits host gives 255.255.255.0 as a netmask (Class C)
16
bits host gives 255.255.0.0 as a netmask (Class B)
Change telnet config password (N)
N
1) Channel configuration for UDP communication
Baudrate
Baud rate of RS232 port.
This is default
9600
on the TIMEmate III.
The baudrate in the TIMEmate setting menu must be the
same as this baudrate.
I/F Mode
Serial interface mode
4C
for internal Ethernet interfaces
Flow
Always
00
Port No
Vicking always uses port number
11333
The computer writes to this port.
ConnectMode
Always
0C
(UDP mode)
Datagram Type
Always
01
Remote IP Address
0.0.0.0
Automatic mode. Data is transmitted back to the
IP address it received data from.
So the computer IP address must not be known.
The TIMEmate only sends data, after the computer send
a command.
Remote Port
Vicking always uses port number
11240
The computer receives data on this port.
Pack Cntrl
Always
00
SendChar 1
Always
0D
SendChar 2
Always
0D
1) Channel configuration for TCP communication
Baudrate
Baud rate of RS232 port.
This is default
9600
on the TIMEmate III.
The baudrate in the TIMEmate setting menu must be the
same as this baudrate.
I/F Mode
Serial interface mode
4C
for internal Ethernet interfaces
Flow
Always
00
Port No
Vicking always uses port number
11333
The computer writes to this port.