Vicking electronics
Pag. 15
Keyboard test
The code of the key pressed is shown.
The following table shows all the keyboard codes for the standard keyboard.
129
131
133
055
056
057
134
135
198
052
053
054
136
137
200
049
050
051
138
139
Exit test
046
048
013
Test the four input ports
Each time one of the four inputs changes a message is shown on the display.
If for example a switch is connected to input 1,
‘
Input 1 Closed
’ is shown if the contact goes from open to closed.
‘
Input 1 Open
’ is shown if the contact goes from closed to open.
Test the six output ports
Press the number of the output you want to change.
An off output will be switch on.
An on output will be switch off.
If you exit this test with backspace all the output are switched off again.
Test the RS232 serial comm. port
This test acts like a mini serial terminal on the extra serial line.
Character received on serial port 2 are displayed on the display, numbers entered on the
TIMEmate keyboard are send on the serial port. The enter key is transmitted as Carriage Return.
This can be used to test the devices you can connect to this port.
3=Debug mode on.
Restart the WORKtime in debug mode.
In this mode the WORKtime beeps every time the ‘N’ command (read data) is received.
So you can check if the server software is running and if the communication link is OK.
4=Exit menu
Leave the settings and selftest menu and resume normal TIMEmate operation.