Trouble shooting 

 

If you can’t communicate with the TIMEmate, check following points: 

 

Check the Baudrate and multidrop address settings of the timemate. 
 Default 9600 baud, Address 00 

 

Check the serial cable, this can be done with a RS232 line tester, which has LED’s for the 
Rxd and Txd lines. 

 

Check if the DIP switches are correctly configured. 

 

For network communication see the chapter ‘setup Ethernet interface’. 

 

Card reader doesn’t work. 

 

If you hear a beep after your read a card and the timemate gives no further response, means 
that the timemate reads the card ok, but the software doesn’t process the data correctly. 

 

Use the selftest in the settings menu. You can check if the hardware works and what data is 
received from the reader. 

 

If the reader is not a standard reader check if you have the correct version of the firmware. 

 
 
 

Summary of Contents for WORKtime 111B

Page 1: ...WORKtime IIIB USER MANUAL Version 1 0 VICKING electronics B 3583 Paal Beringen Schemkensstraat 6 Tel 32 11 450 590 Fax 32 11 450 591 E mail vicking gencom be...

Page 2: ...4 INPUT OUTPUT 5 RELAYS 5 LED S 5 INPUTS 5 CARD READERS 5 SERIAL LINES 7 MOUNTING 8 KEYBOARD 9 COMMUNICATION 10 WRITE TO THE TERMINAL 10 READ FROM THE TERMINAL 10 TROUBLE SHOOTING 12 TIMEMATE IIIB SE...

Page 3: ...with 4 lines of 20 characters and LED back lighting The characters are 5 5 mm high Waterproof membrane keyboard with 6x4 keys Stylish waterproof IP54 housing Reads magnetic cards with ISO track 2 car...

Page 4: ...nics Pag 4 Startup warnings and checks The following things are tested when the TIMEmate starts up If the F1 key is pressed the ethernet setup menu is started If the key is pressed the TIMEmate setup...

Page 5: ...secondary circuit Led s The timemate can drive 2 LED s typically a green and a red Can be used to indicate correct or false input or other special applications Inputs The timemate has 2 non isolated...

Page 6: ...ance directly to the TIMEmate without a doorlock interface see the drawings at the end of the manual Wiegand proximity cards You can connect one internal wiegand reader to the TIMEmate The data from a...

Page 7: ...work from your computer 3 An Ethernet interface can be plugged into the processor board This interface converts the data from serial port 1 to an Ethernet network using the IP protocol family The cabl...

Page 8: ...and then through the wall Or the cables can go through the bottom of the timemate with cable glands If you drill a hole for cables in the TIMEmate and you still want to keep the IP54 waterproof prote...

Page 9: ...fixed function Numbers can be entered with the numerical keys input errors can be corrected with the backspace key and the input can be finished with the enter key The other function keys are transmi...

Page 10: ...rom the terminal The WORKtime terminal accepts this online concentrator compatible communication command to read data from the terminal The data contains entered data and a function code This command...

Page 11: ...es See the WORKmate II manual for the command codes Not all functions of the WORKmate II are supported on the WORKtime No input level detect No input counters No LED drivers No second serial line supp...

Page 12: ...the DIP switches are correctly configured For network communication see the chapter setup Ethernet interface Card reader doesn t work If you hear a beep after your read a card and the timemate gives n...

Page 13: ...g the key for 5 seconds during normal operation You then need to enter the password 1596 1 Setup menu By pressing the up arrow go to the next menu item By pressing the down arrow go to the previous me...

Page 14: ...ameters permanently into flash memory You must press enter in this menu item for the parameter you changed to take effect 2 Selftest menu By pressing the up arrow go to the next menu item By pressing...

Page 15: ...change An off output will be switch on An on output will be switch off If you exit this test with backspace all the output are switched off again Test the RS232 serial comm port This test acts like a...

Page 16: ...of hexadecimal numbers or a Y or N answer See the drawings above for a the keyboard mapping of the A B C D E F Y N letters Press the ENTER key to confirm your input If you reset the TIMEmate before d...

Page 17: ...n for UDP communication Baudrate Baud rate of RS232 port This is default 9600 on the TIMEmate III The baudrate in the TIMEmate setting menu must be the same as this baudrate I F Mode Serial interface...

Page 18: ...eived data from So the computer IP address must not be known The TIMEmate only sends data after the computer send a command Remote Port Vicking always uses port number 11240 The computer receives data...

Page 19: ...mmunication connections Extra connections 1 2 3 4 5 6 7 8 Switch 1 2 3 4 RS232 Switch 5 Ethernet interface Switch 6 7 8 RS485 With this DIP switch you can select the communication method for port 1 Fo...

Page 20: ...or LCD display 4x20 characters includes back light power Connector for keyboard TIMEmate II Reset button Also resets the Ethernet interface 3V Lithium cell to power the memory and Real Time Clock when...

Page 21: ...elow With the program flash exe you can send a timematexx mhx file to the TIMEmate flash memory Select the file with the Open button The correct COM port must be selected with the button Set environme...

Page 22: ...Check if the TIMEmate is configured for RS485 operation DIPswitches You get the best results if you build a RS485 network in this manner The timemate must be connected to each other like a chain you...

Page 23: ...them both to the same T block The maximum length of the network will decrease and the signal will be slightly more distorted compared to the method on the previous page T Block 1 2 3 4 5 6 7 Do not re...

Page 24: ...ter port Connecting the extra serial port port 2 to the RS232 port of a printer PORT 2 Allways RS232 RS232 Brown Brown Yellow Yellow Green Green TIMEmate III RS232 connections 3 TxD 2 TxD 2 RxD 3 RxD...

Page 25: ...ound Black This method is only for short distances only use the cable already connected to the proximity module The advantage of this method is that you don t need a doorlock interface Close jumper 1...

Page 26: ...iring for a Datalogic DLS2000 infrared barcode badge reader 5V 12V GND DCF INPUT 3 BARCODE 0V Clock Data 0V Clock Data PROX2 PROX3 TIMEmate power supply board Connecting an external barcode badge read...

Page 27: ...te and the connected computer Make sure to check that the 3 jumpers on the powersupply board are open Below you can see the wiring for the TIMEmate to the doorlock interface The green wires are needed...

Page 28: ...he wall Do not cross this line The internal circuitbord starts from here 29 20 The timemate hooks into this rim Two 3mm bolds are turned into these holes to mount the timemate TIMEmate III wallmountin...

Reviews: