220011M01 

 

 

 

 

 

High-Precision, Advanced Tuning Fork Balance

 

HJ-KCE/HJR-KCE Series

 

 

 

 

 

 

 

 

 

 

 

Operation Manual

 

 

 

 

 

 

 

 

 

 

 



 

SHINKO DENSHI CO., LTD.

 

● 

To ensure safe and proper use of the balance, please read this 
manual carefully.

 

● 

After  reading  this  manual,  store  it  in  a  safe  place  near  the 
balance, so you can review it as needed.

 

 

IMPORTANT

 

Summary of Contents for HJ-KCE series

Page 1: ...ce HJ KCE HJR KCE Series Operation Manual SHINKO DENSHI CO LTD To ensure safe and proper use of the balance please read this manual carefully After reading this manual store it in a safe place near th...

Page 2: ...your work efficiency Because all the models of the HJ KCE HJR KCE series are dust and water proof conforming to IP65 they can be used in a place exposed to fine dust or to water jets They can also be...

Page 3: ...33 9 Calibrating the Balance 9 1 Span Adjustment with Built in Weight 34 9 2 Span Adjustment with External Weight 34 9 3 Span Test with Built in Weight 35 9 4 Span Test with External Weight 35 9 5 Ca...

Page 4: ...t the user should take to ensure the quality and reliability of the balance Meanings of Symbols Each symbol is accompanied by an instruction Do not disassemble or modify the unit Could cause malfuncti...

Page 5: ...reby causing injury and or damage to the balance Do not use the balance with its adjusters lifted The balance will become unstable preventing accurate measurement Do not submerge the balance Although...

Page 6: ...naccurate measurement If the balance is to be unused for an extended period of time unplug the adapter This conserves power and prevents deterioration Do not use volatile solvents for cleaning The bod...

Page 7: ...2 1 3 Underside common to the pole and separate types Display Adjuster 4 Pan Pole Operation key Level Cover for openings for under weighing The hook for hanging is an option For more information refe...

Page 8: ...ed protect them against water The output connectors are not dust and water proof When the buzzer output is installed or the relay output or RS422A output is used protect the output connectors also aga...

Page 9: ...ce with ISO GLP GMP Lights up when outputs are accompanied by a date and time Blinks during interval output Displays a judgment by the limit function HI OK LO M Displays set values from memory If a va...

Page 10: ...hort press Used to select a function to set Long press Calls functions Zero Tare key Short press Sets a zero point or sets a tare weight Short press Used to enter numerical values Short press Used to...

Page 11: ...tra cable and put it in the cable housing Mount the cable cover vertically on the housing with the both sides slightly opened Mount the base cover in the front of the cable housing so that it is hooke...

Page 12: ...g boards are hooked on the bottom of the cable housing Fasten the two knobs in the connecting fitting Fold the cable and put it in the cable housing with 15 cm of the cable left unfolded in the displa...

Page 13: ...A the unit automatically changes to g Check changes of the display Give the pan a slight press and check that the display is changed Check that the display goes back to zero when you lift your hand St...

Page 14: ...ght and a sample weight excluding tare is referred to as a net weight A gross weight can only be displayed when the balance is used as a weighing machine Put tare on the balance to set the tare weight...

Page 15: ...rge If the influence of the wind or vibration is small set these setting items of Function 1 higher Set these items lower as the influence is increased 4 When you reset the display to 0 or set a tare...

Page 16: ...ions Press the Set key or press the Function key several times until the balance enters measurement mode The setting of functions is completed and the balance goes back into measurement mode The setti...

Page 17: ...umeric 6 digit format Numeric 7 digit format Interface Extended 7 digit numeric format Refer to Section 4 4 Interface Disable the Cal key 1 Span adjustment with built in weight Auto span adjustment Sp...

Page 18: ...ear format Date Display Output in Day Month Year format Disable Time Stamp Output Output measurement data with time The balance goes into standby mode when the AC adapter is inserted Direct Start The...

Page 19: ...ge by deviation values Do not sound a buzzer for rank 1 LO Buzzer for rank 1 Sound a buzzer for rank 1 LO Do not sound a buzzer for rank 2 OK Buzzer for rank 2 Sound a buzzer for rank 2 OK Do not soun...

Page 20: ...continuously when unstable Output is stopped after a single output when the balance is stable even if it is not reloaded Output once when Print key is pressed if the balance is stable Output once imm...

Page 21: ...are key 3 Complete the setting of functions Press the Set key or press the Function key several times until the balance enters measurement mode The setting of Function 2 is completed and the balance g...

Page 22: ...Weighng Mode Unit Function Cumulate Limit Remarks Unit A Weight measuring Unit A B G Gross weight Unit B Weight measuring Weighing machine Unit A S Cumulative weight Display Pcs Counting S Pcs Cumulat...

Page 23: ...nction 1 Put tare on the balance 2 Start sampling Press the Function key for a few seconds When the display indicates release the key The display then blinks Pcs This indicates to put 10 samples on th...

Page 24: ...se the number of samples to increase counting accuracy 2 A series of dots displayed during memory update indicates that the number of samples you added is too small and the counting accuracy is low Ad...

Page 25: ...ss the Function key The balance beeps to indicate that the reference weight was saved and then goes back into measurement mode 5 Put a sample to weigh on the balance The display indicates the weight p...

Page 26: ...s 4 Select digit places to specify a reference weight Press the Function key and the specified number shifts to the left and you can enter the next digit 5 Save the reference weight Press the Set key...

Page 27: ...3 Read the weight Press the Set key After stabilized it start accumulating The cumulative weight is displayed with S sign for several seconds 4 Display the cumulative weight Press the Function key to...

Page 28: ...combination with either of the above judgment methods 1 Put actual samples on the balance Put an actual sample on the balance and save the weight as a limit value 2 Enter values Enter a limit value u...

Page 29: ...r limit The display then indicates and you can now set an upper limit The current upper limit is displayed next to HI 5 Put the upper limit sample on the balance Put the upper limit sample on the pan...

Page 30: ...Set key When a lower limit is saved that value is displayed for a while To set only one point ignore the following steps 6 Set an upper limit The display then indicates and you can now set an upper li...

Page 31: ...Save a lower limit The display first indicates and then the current lower limit blinks Put a sample that provides a lower limit on the balance and press the Function key A lower limit is saved Then g...

Page 32: ...set a lower limit To judge by deviation values enter a value with a minus sign to specify a difference from a reference weight Refer to Caution 9 on page 32 When you enter a upper limit press the Set...

Page 33: ...values when using actual samples press the Function key If you make an operation mistake in entering a limit value press the Set key The operation will be cancelled Then start the operation from the...

Page 34: ...graph Weight range Description Lower limit Weight A bar graph is not displayed Lower limit Weight Upper limit A bar graph to indicate the judgment result is displayed Weight Upper limit The whole bar...

Page 35: ...art span adjustment Press the Cal key The built in weight is enabled and automatically starts span adjustment The display indicates and in sequence When span adjustment is completed the balance goes b...

Page 36: ...ed after is calculated as shown below Error True value Current weight A positive value displayed as an error means that the balance indicates a weight lighter than the actual weight 9 4 Span Test with...

Page 37: ...hat weighs 50 of the weighing capacity or heavier To calibrate more accurately use a weight that is close to the weighing capacity Use a weight of OIML E2 or a higher class to calibrate the built in w...

Page 38: ...me is being displayed 29 or fewer seconds are rounded down to the nearest minute and 30 or more seconds are rounded up to the nearest minute 10 2 Date Setup A date is displayed with a dot The last two...

Page 39: ...to turn off the balance when the balance is left to stand in measurement mode for about 3 minutes This function can only be used when the balance is operated on batteries This function saves battery...

Page 40: ...e displayed in the balance or output to a printer Set date format in Function 1 appropriately as shown below Output in Year Month Day format Output in Month Day Year format Date Display Output in Day...

Page 41: ...ve the settings and go back to measurement mode Press the Set key to return to measurement mode When you press the Print key before saving an interval the original interval is displayed If you press a...

Page 42: ...on key An ID number is displayed If you want to check the ID number press the Function key again The display is changed 3 Start to enter an ID number Press the Zero Tare key You can now enter an ID nu...

Page 43: ...ut Function Remarks 1 2 RXD Input Receiving data 3 TXD Output Transmitting data 4 DTR Output HIGH When the balance is powered ON 5 GND Signal ground 6 7 8 9 Caution Be sure to disconnect the AC adapte...

Page 44: ...IBM PC AT compatible machine Sample wire connection with PC9801 Balance IBM PC AT compatible machine D SUB9P D SUB9P TXD RXD GND DCD RTS CTS DSR DTR RXD TXD GND 3 2 5 1 7 8 6 4 2 3 5 PC9801 Balance D...

Page 45: ...A RS 232C HIGH level data logic 0 5 15 V Low level data logic 1 5 15 V 5 Bit configuration Start bit 1 bit Data bits 8 7 bits 7 bits can be specified for extended 7 digit numeric format Parity bit 0 1...

Page 46: ...nnect a peripheral unit to the balance use a connection cable supplied with the unit 2 You can set a tare range or adjust the zero point from an external device by connecting a contact or a transistor...

Page 47: ...ing terminators CR 0DH LF OAH 1 2 3 4 5 6 7 8 9 10 11 12 13 14 P1 D1 D2 D3 D4 D5 D6 D7 U1 U2 S1 S2 CR LF 2 7 digit numeric format Consists of 15 characters including terminators CR 0DH LF OAH A parity...

Page 48: ...interval While the format with 7 digit value is selected the auxiliary scale is output in this format 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 P1 D1 D2 D3 D4 D5 D6 D7 D8 D9 U1 U2 S1 S2 CR LF 6 Extended...

Page 49: ...en numeric data does not contain decimal places space rather than a decimal point is output to the least significant digit 1 2FH This sign is inserted before the auxiliary scale interval in the Format...

Page 50: ...r Indicates that data other than S2 is invalid SP 20H No status specified Data that is independent of whether the weighing condition is stable or not such as cumulative values and unit weights is inde...

Page 51: ...esponse to an input command in one second after it is transmitted However if the balance receives a tare range command when the Set Tare function is set so that the display is reset to 0 when the bala...

Page 52: ...9 45H 30H 39H 30H 39H Errors other than E01 Numeric format error Processing interrupted Processing terminated abnormally Other errors 2 ACK NAK format Consists of 1 character Does not contain a termin...

Page 53: ...is stabilized again even if it is not reloaded the output includes zero 0 6 4FH 36H Output once when the balance is stable Output continuously when unstable Output is stopped after a single output wh...

Page 54: ...unit weight Error 1 Mode 3 M3 can be specified only when the accumulation function is enabled If the accumulation function is not enabled an error is returned 2 If a unit is not specified for unit B t...

Page 55: ...mand Command Main Body 1st character 2nd character Code Description Value Response C 0 43H 30H Disable the Cal key 1 C 1 43H 31H Span adjustment with built in weight Auto span adjustment C 2 43H 32H S...

Page 56: ...O1 CR LF Set the balance to continuous output O8 CR LF Output data once immediately IA 12 34 56 CR LF Set an interval of 12 hrs 34 min 56 sec OA CR LF Start the interval function DD CR LF Output the d...

Page 57: ...Measurement Data in Compliance with ISO GLP GMP 1 Set Function 1 Set the ISO GLP GMP compatible item to and set the GLP compatible item for measurement data to 2 Header output Press and hold the Print...

Page 58: ...I M E 1 6 5 7 19 20 S I G N A T U R E 21 22 23 24 25 26 27 28 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 1 2 3 4 2 0 0 3 0 6 2 6 5 1 6 5 6 6 S H I N K O D E N S H I 7 8 X X X X X X H J R 1 7 K C E 9 X X X X...

Page 59: ...X X X X X X X X 10 I D X X X X X X 11 12 13 14 X X X X X X X X X X g 15 16 X X X X X X X X X X g 17 18 19 2 0 0 3 0 6 2 6 20 1 6 5 7 21 22 23 24 25 26 27 28 29 30 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15...

Page 60: ...S H I N K O D E N S H I 7 8 X X X X X X H J R 1 7 K C E 9 X X X X X X X X X X 10 I D X X X X X X 11 12 13 X X X X X X X X X X g 14 15 16 2 0 0 3 0 6 2 6 17 1 6 5 8 18 19 20 21 22 23 24 25 26 27 1 2 3...

Page 61: ...charge batteries after they are recharged because that may shorten their life 2 When you use the balance for the first time after you purchase it battery operation time may be shorter than usual becau...

Page 62: ...mple A section of the mechanism is damaged Check the total weight Execute tare subtraction again Contact our technical service personnel or your local dealer is displayed A foreign object is caught be...

Page 63: ...t difficult to remove to protect against dust and water If the problem is cleared by removing the rubber cap replace the filter with a new one If the problem is not cleared by removing the cap it has...

Page 64: ...ies Can be selected from 5 levels Double range Calibration Span adjustment with the built in or an external weight OIML class Class II Model Item HJ 17K S CE HJ 22K S CE HJ 33K S CE HJ 62KD S CE Weigh...

Page 65: ...extend the balance cable 10 m PU cable used to extend the balance cable These optional PU cables are only available for the separate type Hook for hanging Battery option Buzzer option Limit contact ou...

Page 66: ...The view of the table Top line Capacity Middle line Verification scale interval Bottom line Auxiliary scale interval 18 Conversion Table of Units Unit gram kilogram carat 1g 1 1000 5 1kg 0 001 1 0 005...