Seeker X User’s Guide
22137808, Rev. 001
Feb 2020
34
Chapter
2 Using Your Seeker X
Seeker X setup
You must configure the settings of the Seeker X using the Seeker Setup software. The Seeker X
comes from the factory with default settings, but it is likely they will need to be customized.
See the
Seeker Setup Software User’s Guide
for more information.
Basic operation
Power
Press and hold the
POWER
button until you hear three ascending tones. Within a few
moments your Seeker X will startup into the RF Signal Measurement mode.
To turn off the meter, press and hold the
POWER
button until you hear three descending
tones as the meter turns off.
Low battery warning
A very low battery may cause the Seeker X not to turn on. When
the battery is too low for your Seeker X to function,
LO
BATT
shows on the display. The battery must be charged for a few
minutes before using again.
Seeker MCA III communication successful
(optional)
After placing the Seeker X in the Mobile Mount and upon
successful communication with the optional Seeker MCA III, the
screen shown here is displayed.
NOTE:
Ensure that the Seeker X is properly seated in the Mobile
Mount, otherwise the Seeker X will display an error
message and it will not be able to communicate with the
Seeker MCA III.
Low battery
SEEKER X
μV
m
dB
NOISE
FREQ
PK
DIST
GPS
Communication
successful
SEEKER X
μV
m
dB
NOISE
FREQ
PK
DIST
GPS
Summary of Contents for Seeker X
Page 1: ...Seeker X Digital Leakage Detection System User s Guide ...
Page 6: ...Seeker X User s Guide 22137808 Rev 001 Feb 2020 6 ...
Page 10: ...Seeker X User s Guide 22137808 Rev 001 Feb 2020 10 Contents ...
Page 18: ...Seeker X User s Guide 22137808 Rev 001 Feb 2020 18 About this Guide ...
Page 32: ...Seeker X User s Guide 22137808 Rev 001 Feb 2020 32 Chapter 1 Quick Tour ...
Page 52: ...Seeker X User s Guide 22137808 Rev 001 Feb 2020 52 Chapter 2 Using Your Seeker X ...
Page 56: ...Seeker X User s Guide 22137808 Rev 001 Feb 2020 56 Chapter 3 Leakage Testing ...