Leakage Testing
Chapter 5
Before You Begin Leakage Testing
• A low battery may cause the Seeker D Lite to NOT turn on. Try charging your battery for
3 hours to see if that fixes the problem.
• The Seeker D Lite will retain the setup from when the meter was last shut off. For
example, if you were testing frequency preset number two and then turned off your
Seeker D Lite, when you turned it back on again the meter would automatically begin
testing that same preset.
Testing For Leaks
The Seeker D Lite should be configured with the Seeker Setup software before beginning
leakage testing.
1. Turn on the Seeker
D Lite
Press the red
ON/OFF
button until you hear 3 ascending tones. The Seeker D Lite will
power up in RF Level Measurement Mode.
2. Confirm the desired frequency preset (0–9) is selected
If using the Seeker D Lite for the first time, the default frequency preset during
configuration with Seeker Setup software will be selected.
If the Seeker D Lite has been used since configuration with Seeker Setup software, the
last frequency used will be selected.
The CT-4 Digital Channel Tagger must be installed and set up
within the system before testing for leaks. The Seeker D Lite
Source Transmitter can also be used at the ground block.
For more information about using the Preset Frequency
or Channel Tag features, see Chapter 3: Seeker Operation,
Display Modes.
Summary of Contents for Seeker D Lite
Page 1: ...Seeker D Lite In Home Leakage Detector User s Guide ...
Page 8: ...Seeker D Lite User s Guide Document Num Rev 4 May 2018 Page 8 ...
Page 12: ...Seeker D Lite User s Guide Document Num Rev 4 May 2018 Page 12 ...
Page 41: ...Seeker D Lite User s Guide Document Num Rev 4 May 2018 Page 41 ...