Seeker D Lite User's Guide
Document Num., Rev. 4
May 2018
Page 36
3. Confirm the Seeker is in the RF Level Measurement mode
The Antenna icon on the display should be flashing for the RF Level Measurement
mode. If necessary, use the
SELECT
button
to move to the Measurement mode (or let it
time out and return to Measurement mode automatically).
4. Begin leakage testing
Move the Seeker D Lite around the test area. If the detected leakage level exceeds the
squelch levels, the Seeker D Lite will alarm.
The frequency of the alarm tone will increase as the detected signal strength increases.
Continue to move the Seeker D Lite in the direction producing the highest tone
frequency to locate the source of the leak.
5. Cruise Mode
If an alarm is not detected in Measurement mode and you wish to continually monitor
leakage levels with your Seeker D Lite, you can select the Cruise mode to shutdown the
display and conserve the battery charge.
To select Cruise mode from the Measurement mode, press the red on/off button until 2
beeps are heard and CR is displayed.
If a signal greater than the squelch level is detected in Cruise mode, the Seeker D Lite
will beep to alert the user. Measurement mode can then be used to measure and find
the leak.
6. Turn OFF the Seeker D Lite
When testing is complete, turn off the Seeker D Lite by holding down the red
ON/OFF
button until you hear 3 descending tones.
The auto time out from the Measurement mode setting to
Cruise mode or off can be programmed via the Seeker Setup
software.
Summary of Contents for Seeker D Lite
Page 1: ...Seeker D Lite In Home Leakage Detector User s Guide ...
Page 8: ...Seeker D Lite User s Guide Document Num Rev 4 May 2018 Page 8 ...
Page 12: ...Seeker D Lite User s Guide Document Num Rev 4 May 2018 Page 12 ...
Page 41: ...Seeker D Lite User s Guide Document Num Rev 4 May 2018 Page 41 ...