64
MPOLx-85 / MPOLx-85P
10 S
PECIFICATIONS
L
OSS
/L
ENGTH
Loss/Length
Power Meter
Test Wavelength
Multi-mode: 850/1300 nm
Single-mode: 1310/1550 nm
Testing Speed for 12 Channels
6 s max.
Measurement range Loss
1)
1) Measurement Range Length 0 to 10 dB
Multi-mode 0 to 25 dB
Single-mode 0 to 45 dB
Resolution
0.01 dB
Loss Measurement accuracy
2)
2) excluded Fiber Connector Uncertainties
±0.15 dB
Length Measurement
accuracy
1)
±1.5 m ±1% of length
Detector type
InGaAs
Power measurement range
-50 to +3 dBm
Max. permitted input level
+3 dBm
Overall measurement
uncertainty at calibrated
wavelengths
-5° C to +45 °C
Multi-mode: ± 0.7 dB ± 1 nW
Single-mode: ± 0.6 dB ± 1 nW
Linearity
±0.15 dB
Wavelength range
850nm…1550 nm
Wavelength settings
850 nm, 1300 nm, 1310 nm, 1550 nm
Calibrated wavelengths
Multi-mode: 850 nm, 1300 nm
Single-mode: 1310 nm, 1550 nm
Display resolution
0.01 dB / 0.001 μW
Measurement units
dB, dBm, W
Power meter functions
Abs, rel, pass/fail
Auto functions
1)
1) Works in conjunction with Viavi Laser/LED sources
Auto-λ function:
auto single-wavelength detection
Multi-λ function:
auto multi-wavelength detection
Tone detection
270 Hz, 1 kHz, 2 kHz
Warm up time
20 min.
Optical interface
MPO-12 interface pinned.
Compatible with
50/125 μm/PC multi-mode MPO-12,
9/125 μm/APC single-mode MPO-12.
MTP adapter with shutter