50
Feeder X3 hard coal
[%]
P 174
It regards the percentage value of output.
The value 66 represents 66% output and feeder standstill time of parameter 175 is
assigned to this value. Note: This parameter cannot be changed
Feeder Y3 hard coal
[s]
P 175
Setting the feeder standstill time for
Č
U as the fuel relating to 66% output
Feeder X4 hard coal
[%]
P 176
It regards the percentage value of output.
The value 100 represents 100% output and feeder standstill time of parameter
177 is assigned to this value. Note: This parameter cannot be changed
Feeder Y4 hard coal
[s]
P 177
Setting the feeder standstill time for
Č
U as the fuel relating to 100% output
Feeder runtime in the attenuation regime– hard coal
[s]
P 178
Setting the feeder runtime in the attenuation regime for
Č
U as the fuel
Standstill time(delay) of feeder in the attenuation – hard coal
[min.]
P 179
Standstill time of the feed screw in the attenuation regime for
Č
U as the fuel
Ventilator X1 hard coal
[%]
P 200
It regards the percentage value of ventilator output
The value 0 represents min. ventilator output and actual ventilator output of
parameter 201 is assigned to this value. Note: This parameter cannot be changed
Ventilator Y1 hard coal
[%]
P 201
Setting the actual ventilator output for
Č
U as the fuel relating to 0% ventilator
output
Ventilator X2 hard coal
[%]
P 202
It regards the percentage value of ventilator output
The value 33 represents 33% ventilator output and actual ventilator output of
parameter 203 is assigned to this value.Note: This parameter cannot be changed
Ventilator Y2 hard coal
[%]
P 203
Setting the actual ventilator output for
Č
U as the fuel relating to 33% ventilator
output
Ventilator X3 hard coal
[%]
P 204
It regards the percentage value of ventilator output
The value 66 represents 66% ventilator output and actual ventilator output of
parameter 205 is assigned to this value. Note: This parameter cannot be changed
Ventilator Y3 hard coal
[%]
P 205
Setting the actual ventilator output for
Č
U as the fuel relating to 66% ventilator
output
Ventilator X4 hard coal
[%]
P 206
It regards the percentage value of ventilator output
The value 100 represents 100% ventilator and actual ventilator output of
parameter 207 is assigned to this value.Note: This parameter cannot be changed
Ventilator Y4 hard coal
[%]
P 207
Setting the actual ventilator output for
Č
U as the fuel relating to 100% ventilator
output
Ventilator slowing-down in the attenuation regime– hard coal
[s]
P 208
Setting the ventilator slowing-down in the attenuation regime against the feeder
runtime in the attenuation regime
Ventilator output in the attenuation regime – hard coal
[%]
P 209
Setting the ventilator output in the attenuation regime