49
Feeder runtime in the attenuation – lignite
[s]
P 158
Setting the feeder runtime in the attenuation regime for HU fuel
Standstill time(delay) of feeder in the attenuation – lignite
[min.]
P 159
Standstill of feed screw in the attenuation regime for HU fuel
Ventilator X1 lignite
[%]
P 160
It regards the percentage value of ventilator output.
The value 0 represents min. ventilator output and the actual ventilator output of
parameter 161 is assigned to this value. Note: This parameter cannot be changed
Ventilator Y1 lignite
[%]
P 161
Setting the actual ventilator output for HU fuel relating to 0% ventilator output
Ventilator X2 lignite
[%]
P 162
It regards the percentage value of ventilator output
The value 33 represents 33% ventilator output and the actual ventilator output of
parameter 163 is assigned to this value. Note: This parameter cannot be changed
Ventilator Y2 lignite
[%]
P 163
Setting the actual ventilator output for HU fuel relating to 33% ventilator output
Ventilator X3 lignite
[%]
P 164
It regards the percentage value of ventilator output
The value 66 represents 66% ventilator output and the actual ventilator output of
parameter 165 is assigned to this value. Note: This parameter cannot be changed
Ventilator Y3 lignite
[%]
P 165
Setting the actual ventilator output for HU fuel relating to 66% ventilator output
Ventilator X4 lignite
[%]
P 166
It regards the percentage value of ventilator output
The value 100 represents 100% ventilator output and the actual ventilator output
of parameter 167 is assigned to this value. Note: This parameter cannot be
changed
Ventilator Y4 lignite
[%]
P 167
Setting the actual ventilator output for HU relating to 100% ventilator output
Ventilator slowing-down in the attenuation regime– lignite
[s]
P 168
Setting the ventilator slowing-down in the attenuation regime against the feeder
runtime in the attenuation regime
Ventilator output in the attenuation regime– lignite
[%]
P 169
Setting the ventilator output in the attenuation regime
Feeder X1 hard coal
[%]
P 170
It regards the percentage value of output.
The value 0 represents min. output and feeder standstill time of parameter 171 is
assigned to this value. Note: This parameter cannot be changed
Feeder Y1 hard coal(
Č
U)
[s]
P 171
Setting the feeder standstill time for
Č
U fuel relating to 0% output
Feeder X2 hard coal
[%]
P 172
It regards the percentage value of output.
Value 33 represents 33% output and feeder standstill time of parameter 173 is
assigned to this value. Note: This parameter cannot be changed
Feeder Y2 hard coal
[s]
P 173
Setting the feeder standstill time for
Č
U fuel relating to 33% output