26
10.
Before filling the system with water,
switch-over the control lever of the Honeywell V 4044F three-way valve from the AUTO
position to the MAN-OPEN position
(as far as the hot water preparation is installed)
Fig. №. 23
Connecting to the heating system and mounting of the draught diverter
number of sections
2
3
4
5
D
80
110
130
160
T
240
325
410
495
T1
115
158
200
243
B
335
420
505
590
Fig. №. 24
Sizes for connection
A - water stack heater
B - heating system
AB - boiler
Fig. №. 25
Honeywell V 4044F three-way valve
Fig. №. 26
Control of Honeywell V V4044F three-way valve
11.
Filling the heating system with water.
The heating system has to be thoroughly flushed to wash-away all impurities that could be
deposited in the distributions or the heating radiators and consequently could cause a damage of the pump.
Water serving for watering the heating system has to be clean and colorless, without suspended substances, without oil and without
chemically aggressive substances.
Its hardness must comply with ČSN 07 7401 and in case that water hardness does not comply with
the requirements, water has to be prepared. Even multiple heating water with higher hardness will not prevent from excluding salts on the
walls of the boiler drum. Sedimentation of 1 mm of limestone reduces the heat transmission from metal to water by 10% in the given
place.
position
AUTO
position
MAN-OPEN
Supporting board for sensor of
flue-gases reverse flow safety
device
Automatic deaeration
valve
T-piece
Horizontal draught
diverter
ТЕ branch
reduced 90
Output valve
Conductor color:
Green-yellow
Brown
Blue
Orange
Grey