3022CS AUTOMATIC UNIT
20
8.6.2. INPUTS CONTROL FROM THE MOTOR PANEL
Through the arrow down, place the flashing cursor beside the Test Positions Test.
The display changes as follows:
Confirm with the key
ENT
The display changes as follows:
In order to check the working please remember that:
-
the position 1 is NOT used.
-
In the position 2 the INPUT relative to the SIGNAL MACHINE IN ROTATION is visualized.
The value is 1 (on) when the OUTPUT is active.
Press the control pedal and when the machine is rotating the value becomes 1.
-
In the position 3 the input relative to the function STEP BY STEP MOTOR IMPULSES is visualized.
The value is 1 (ON) only when the motor panel send an impulse through the exit CP
Rotate slowly with the hand the wheel of the machine to change the value
To exit the function and return to the principal Menu press the key
ENT
8.6.3.INPUTS CONTROL TO THE ELECTROVALVES
With the arrow down place the flashing cursor beside the Outs Test.
The display changes as follows:
Confirm with the key
ENT
The display changes as follows:
In order to check the working remember that the outputs have the following setup:
-
In the position 1 the output relative to the UNSTITCHING function is visualized.
Press the key
1
to enable / disenable the function.
The value is 1 (on) when the function is enabled while the value is 0 (off) when it is disenabled.
-
In the position 2 the output relative to the PINCER function is visualized.
Press the key
2
to enable / disenable the function.
The value is 1 (on) when the function is enabled while the value is 0 (off) when it is disenabled.
-
In the position 3 the output relative to the CUTTING function is visualized.
Press the key
3
to enable / disenable the function.
The value is 1 (on) ) when the function is enabled while is 0 (off) when it is disenabled.
-
In the position 4 is visualized the output relative to the SAFETY CUT DETECTOR function
Press the key to enable / disenable the function.
The value is 1 (on) ) when the function is enabled while is 0 (off) when it is disenabled.
NOTE:
The function 3 CUT is activated only if the function 4 SAFETY CUT DETECTOR is active too.
To exit the function and return to the principal Menu press the key
ENT
LS01
MITSUBISHI GMFY
test inputs
test position
inputs from motor
0 0 0
inputs from motor
1 2 3
LS01
ELECTROVALVES
test position
test Outs
Outputs
0 0 0 0 0
Outputs
1 2 3 4 5
Summary of Contents for 3022 Series
Page 60: ...3022CS AUTOMATIC UNIT 60...
Page 61: ...3022CS AUTOMATIC UNIT 61...