3022CS AUTOMATIC UNIT
15
8.3.6.
HOW TO SET THE CUT AND UNSTITCHING COUNTER IN THE PROGRAM
N°4
Inside the program in execution are used two different types of counter,
A
and
B
.
Every counter can be used many times in a sequence, with a maximum value of 250 stitches/setting.
Their purpose is to keep or delay the insertion of a function.
ATTENTION:
For the correct insertion always check trough the legend of the program in use the model and number of
the counter to modify.
8.3.6.1. SETTING OF THE COUNT INITIAL UNSTITCHING LENGHT MATERIAL INSERTION (PROGRAM 4)
Press the key
PARAMETER SETUP
, on the motor panel, then press FOUR (4) times the arrow up
On the display appears:
Press the key
ENTER
On the display appears
:
The number on the left identifies the line of the program, while the number on the right identifies the column of the
directions,
where the time-switch is selected, press the key
D
On the display appears
:
Set with A and B the number of the line to modify
Number
9 – 2
in this case the section of the initial unstitching preparation (150) must be changed.
Press
ENTER
On the display appears the logic number of the line selected:
Set with B, C and the required value, for example
180
press
ENTER
Press the key
PARAMETER SETUP
twice to exit
Switch the motor off and wait until the display switches off too, then switch the unit on again.
8.3.6.2. SETTING OF THE COUNT INITIAL UNSTITCHING LENGHT PRESSER FOOT LOWERING (PROGRAM 4)
Press the key
PARAMETER SETUP
, on the motor panel and press FOUR (4)times the key up
On the display appears:
Press the key
ENTER
On the display appears:
The number on the left identifies the line of the program, while the number on the right identifies the column of the
directions,
where the time-switch is selected, press the key
D
On the display appears:
Set with A and B the number of the line to modify
number
13 – 2
in this case the unstitching length section must be changed (180)
press
ENTER
On the display appears the logic number of the line selected:
Set with B, C and D the required value for example
180
press
ENTER
Press the key
PARAMETER SETUP
twice to exit
L 1 2 9 9
n
1 - 1
n
1 -
2
T L 0 6 0
L 1 2 9 9
n
1
-
1
n
1 -
2
T
L
0
6 0
Summary of Contents for 3022 Series
Page 60: ...3022CS AUTOMATIC UNIT 60...
Page 61: ...3022CS AUTOMATIC UNIT 61...