3022CS AUTOMATIC UNIT
19
Confirm with the key
ENT
8.6. TEST FUNCTION
At the ignition of the machine on the display appears:
Press the key
TEST
and keep it pressed until the second acoustic signal
The display changes as follows:
Insert with the keyboard the access code (CODE used
4 – 7 – 1 – 1)
The display changes as follows:
Trough the directional keys (Up/Down) shift the flashing cursor on the Test to check, selecting it between the different
options in the following list.
Test inputs
select the INPUTS control (photocells) at the panel
Test position
select the logic INPUTS control that comes from the motor panel
Test outs
select the OUTPUTS control at the electro valves
Test speed
select the SPEED control that have been settled through logical output to the motor panel
8.6.1.INPUTS CONTROL FROM PHOTOCELL OR DETECTOR
Through the directional arrow place the flashing cursor beside the inputs Test.
The display changes as follows:
Confirm with the key
ENT
the display changes as follows:
In order to check the working remember that:
-
In the position 1 the input relative to the UNSTITCHING photocell is visualized.
The value is 1 (on) when it is covered while is 0 (off) when uncovered.
-
In the position 2 the input relative to the INTERMEDIATE STOP is visualized.
The value is 1 (on) ) when it is covered while is 0 (off) when uncovered.
-
In the position 3 the input relative to the CUTTING photocell is visualized.
The value is 1 (on) when it is covered while is 0 (off) when uncovered.
To exit the function and return to the Principal Menu press the key
ENT
VI.BE.MAC. 3022
1, PROGRAM 3
PASSWORD
* * * *
test inputs
test position
test position
test outs
test outs
test speed
test speed
test end
Green LED on:
Photocell OFF = 0
Red and Green LED on:
Photocell ON = 1
LS01
PHOTOCELLS
test inputs
External Inputs
0 0 0 0
External Inputs
1 2 3 4
test inputs