38
■
Maintenance
Cleaning electrode needle
To keep the performance of static elimination of the ion bar, clean the electrode needle once a
month. The cleaning frequency depends on the environment where the ion bar
Be very careful when cleaning the needle because its tip is very keen.
Cleaning procedure
(1) Be sure to power off the ion bar and unplug the power supply cable before
cleaning the electrode needle.
(2) Dip a cotton bud in alcohol (do not use pure alcohol or acetone).
(3) Clean the electrode needle by rotating the cotton bud.
Be sure not to apply a force to the needle to avoid damaging the needle or
socket.
(4) If the needle is damaged while cleaning it or it is already worn, replace it with a
new socket.
(5) After cleaning the needle, wait until it gets dry before supplying power.
(6) keep a maintenance record so that the cleaning history can be checked later.
Replacing electrode needle
In general, the electrode needle must be replaced once a year. However,
frequency depends on the environment where the ion bar is installed.
Be very careful when replacing the needle because its tip is very keen.
Replacing procedure
(1) Turn the electrode needle socket with
fingers counterclockwise by 90º.
(2) Pull the unit out.
*Reverse the above steps to install
the new socket.
Storage
Storage
CAUTIONS
ROHIBITED
Do not store the ion bar in the following places. Doing so may cause a failure.
• Where exposed to strong vibration or shock.
• Where temperature and humidity are outside the specified ranges.
• Where dewing occurs.
• Where temperature fluctuates sharply.
• Where there is the possibility of ignition or explosion of flammable
solvents, dust, etc.
• Where there is heavy dust or smoke.
• Where possibly wet by water, oil, chemicals, etc.
• Where strong electric or magnetic fields are generated.
, clean the electrode needle once a
the ion bar is installed.
and unplug the power supply cable before
Be sure not to apply a force to the needle to avoid damaging the needle or
(4) If the needle is damaged while cleaning it or it is already worn, replace it with a
a maintenance record so that the cleaning history can be checked later.
In general, the electrode needle must be replaced once a year. However, the replacement
in the following places. Doing so may cause a failure.
Where temperature and humidity are outside the specified ranges.
Where there is the possibility of ignition or explosion of flammable
Where strong electric or magnetic fields are generated.