31
Installation
Power supply cabling
WARNING
REMEMBER
Be sure to use 24 VDC ± 5% power supply to avoid a fire or electric
shock.
REMEMBER
Be sure to stop the power supply before a cabling work to avoid an
electric shock.
REMEMBER
Be sure to follow the electric facility technical standard as well as any other
supplemental regulations to avoid an electric leak, electric shock, or fire.
Checking specifications
Check that the power supply specifications of the ion bar is in accordance with the power supply provided.
Power supply cable
Please insert the connector of the cable to the power supply terminal, and connect the wires to
power supply.
Daisy chain
The power supplies for ion bars can be linked in up to 4 in sequence.
Using the daisy chain connection, please use Category 5E cable to purchase the market.
A cable length is up to 10m. May not work using the cables are more than 10m.
AC ITapter (option)
Optional AC adapter is available. Please
wire as shown on the right when using.
*AD24-ITE for one bar. AD24-IT19E for
three bars.
Air piping
CAUTIONS
REMEMBER
Be sure to use a pressure-proof air hose. A non-pressure-proof hose may
cause breakage of the hose or air leak.
Air used
The ion bar requires supply of clean compressed air for air blow operation.
Supply air with pressure up to 0.3 MPa.
* If the air is supplied intermittently, please supply under 0.2MPa.
Use an air drier to remove moisture from the air (dew point temperature: -15ºC or lower).
Use a mist separator (0.3 μm) to remove impurities from the air.
Supply air at temperature range within 0 - 40ºC.
Hose used
Use a pressure-proof
hose with the external diameter 8 mm φ x internal diameter 6 mm φ
Hose connection
Connect the hose to the one-touch joint
(air supply) at the end of the ion bar.