Operation
The duty ratio means the duration time of Positive and Negative respectively.
t1:t2
=
50
:
50
The duration time of Positive and
Negative just same.
t1:t2
=
51
:
49
The duration time of Positive side is 2
longer than that of Negative.
It means that the quantity of Positive ions
is much more than that of Negative.
t1:t2
=
49
:
51
The duration time of Negative side is 2
longer than that of Positive.
It means that the quantity of Negative ions
is much more than that of Positive.
Auto balance mode
If you enable auto-balanced mode with DIP switch, the pulse ratio will be automatically adjusted by
the potential of charged materials.
If there is no charge,
Pulse ratio is equal.
Ion balance indicator is illuminated in the
middle.
If there is positive-charged material,
Negative side ratio increases, then the
ion bar is quickly neutralizing.
Ion balance indicator is illuminated in the
left side (-).
If there is negative-charged material,
Positive side ratio increases, then the ion
bar is quickly neutralizing.
Ion balance indicator is illuminated in the
right side (+).
DIP switch for A/BAL must be turned on when there is no charge. Because the high voltage
consumption is measured for 10 seconds after turning on it, and stored as “reference value“.
A/BAL mode will not work in case the charged object is less than ±3kV or away more than
100mm.
Positive ion voltage level setup
Pressing the SET button repeatedly until "
P
-xx" appears on the display.
While "
P
-xx" is shown, press the UP or DOWN button to change the positive ion voltage level of
the ion bar (1-10).
Pressing the SET button again accepts the displayed positive ion voltage level and resumes the
ion bar operation in a few seconds.
* You cannot change the positive ion voltage level from the remote controller.
example
P-01
→
P-02
→
P-03
→・・・→
P-08
→
P-09
→
P-10