23
Product Features
Product features
Form
●
Slimmed down
・
Compact and lightweight design allows installation in a space-saving on the production
equipment or the clean bench. Mounting brackets is included.
Performance
●
Pulse AC scheme
・
The static eraser uses the pulse AC scheme to generate positive and negative ions from
individual electrode needles. Quick removal of static electricity can be assured by maintaining
uniform ion balance.
●
Frequencies
・
The static eraser allows setting thirteen types of frequencies (0.1 to 50Hz). This allows erasing
static electricity according to the installation distance and charge quantity. The static eraser can
address installation distances from 50 mm up to 2000 mm.
●
Duty ratio
・
The most suitable ion balance can be maintained by adjusting the duty ratio.
●
Voltage level
・
The static eraser allows changing the positive and negative voltages applied to the electrode
needle (from the operation panel only). The most effective removal of static electricity for each
environment is possible by changing the voltage output (8.0 to 12.5kV p-p).
●
Air purge function
・
The static eraser prevents particles from adhering to the electrode needle by purging air toward
the tip of the electrode needle. Air purged from the static erasing bar spreads within the static
erasing area to accelerate static erasure. The maximum supply pressure of the air is 0.3 MPa.
Management
●
Low-voltage input
・
Low-voltage input (24 VDC) ensures easy and safe installation on equipment.
●
Parallel power connection function (Daisy Chain)
・
C-series can be connected up to Max. 4 ion bars by parallel power connection function.
●
Easy replacement of electrode needle
・
Electrode needle socket allows one-touch replacement.
●
High-voltage abnormality alarm output
・
When an abnormal condition is detected at the high-voltage output, the H/V lamp lights and an
alarm signal is output. By setting the DIP switch appropriately, the ion bar can be stopped when
a high-voltage alarm is generated.
●
Tip cleaning alarm output
・
Tip cleaning alarm function at the set time. The TIP/C lamp lights and an alarm signal is output
by setting the DIP switch.
●
Address setting
・
When using multiple units, you can set the address to identify each bar (1-16).
●
Card-type remote controller
・
The card-type remote controller which can be put into a pocket is used to control the ion bar
from a distant location.
●
RoHS/CE
・
This product complies with each directive.
Summary of Contents for Stat-Clean C-100
Page 6: ...6 外観寸法 外観寸法 ...