35
■
Operation
negative ion voltage level setup
Pressing the SET button repeatedly until "
n-
xx" appears on the display.
While "
n-
xx" is shown, press the UP or DOWN button to change the negative ion voltage level of
the ion bar (01-10).
Pressing the SET button again accepts the displayed negative ion voltage level and resumes the
ion bar operation in a few seconds.
* You cannot change the negative ion voltage level from the remote controller.
example
n-01
→
n-02
→
n-03
→・・・→
n-08
→
n-09
→
n-10
Voltage levels of positive and negative ions
Refer to the table below to set the voltage levels.
Level
Positive ion
(
kV
)
negative ion
(
kV
)
Vpp
(
kV
)
01
4.00
4.00
8.0
02
4.25
4.25
8.5
03
4.50
4.50
9.0
04
4.75
4.75
9.5
05
5.00
5.00
10.0
06
5.25
5.25
10.5
07
5.50
5.50
11.0
08
5.75
5.75
11.5
09
6.00
6.00
12.0
10
6.25
6.25
12.5
Recommended distance and frequency
Removal
speed
Location
Installation location
(mm)
Recommended
frequency (Hz)
High
Film or seat production line
Near
50-300
20, 30, 35, 40, 45, 50
Clean bench
Middle
600-750
8, 10
Low
Ceiling of clean room
Far
900-1500
0.1, 0.3, 1, 3 ,5