RFSDV34 Freestanding Direct Vent Gas Stove
10003550
Instructions for RCSITEA
RFSDV34TSR Series
CAUTION:
The RCSITE is only certified for use on vented
heater rated equipment.
This remote control system provides a safe, reliable and
user-friendly remote control for millivolt valve gas appli-
ances, blower speed and flame height adjustment. The
system can be manually or thermostatically turned on and
off with the transmitter.
Carefully inspect the contents for shipping damage. If any
parts are missing or damaged, immediately contact your
dealer. Do not attempt to install any part of the kit unless
all parts are in good condition. Refer to instructions pro-
vided with the kit for complete installation instructions.
WARNING: Make sure 10V AC fan and SIT valve are
correct. If not wired correctly, damage to receiver could
result. Make sure the wires do not contact the appliances
any place other than at the terminals. Exposure to tem-
peratures higher than 50°F (105°C) may cause the re-
ceiver to malfunction and cause possible fire hazard.
Remote Transmitter
Install Batteries
The remote transmitter uses three (3) “AAA” batteries.
1. Press down the battery door tab
and pull out to remove the battery
door. (Fig. 31)
. Install the batteries as indicated
on transmitter.
3. Close the battery door by snap-
ping in place.
4. When three (3) batteries are in-
stalled, the transmitter will initial-
ize for 10 seconds and then is
ready for use.
5. The batteries should be replaced
at least once every 1 months or
when the low battery indicator is displayed.
Setting Privacy (DIP) Switch on Receiver and Trans-
mitter
The remote receiver and transmitter privacy (DIP) switch-
es are preset at the factory. In the event of activation or
interference from other nearby transmissions, reset the
code using the following procedure:
1. There are four (4) switches on the transmitter and sev-
en (7) switches on the receiver. Figure 33. Switches
#1, #, #3 and #4 on both transmitter and receiver are
privacy switches and #5, #6, #7 on the receiver are
blower switches and should not be moved. These are
preset for the installed blower.
ST1088
RCSITE battery tab
Battery
Door
Tab
Fig. 31
Bat-
tery door tab.
. Slide the privacy code switches (1,,3 & 4) on the
transmitter and receiver to your choice of ON or OFF
position. All switches are preset to “ON” for both the
transmitter and receiver.
3. The privacy code switches (1,,3 &4) on the transmit-
ter and on the receiver must match in order for the
system to work.
4. To check, press either the ON or OFF button on the
transmitter and the receiver indicator light will blink. If
not, repeat Step .
5. The system is now ready to operate.
NOTE:
Refer to optional 6 Hour Shutdown.
WARNING:
Do not use two () or more remote
control systems in the same area with the same
dip switch settings, they will communicate with
each other. This may cause the appliances to
malfunction.
Reset Button
The reset button can be used to reset the transmitter if
transmitter is not working properly. The reset button is lo-
cated behind the battery door cover in the lower left cor-
ner of battery compartment. Using a paper clip, press the
reset button and the transmitter will reset and initialize for
10 seconds before it can be used.
Operation
Transmitter
General
The RCSITE Remote Control has
two () operating modes: Manual
and Thermostatic. The control sys-
tem can be set to temperature rang-
es between 45°F and 90°F. The
blower speed and flame height can
be adjusted in either the manual or
thermostatic mode.
FAN
AUTO
AMBIENT
ST1090
RCSITE remote
ON
FLAME
OFF
Fig. 33
RCSITE
remote transmitter.
ST1089
RCSITE dip switches
ON
DIP
ON
DIP
ON
DIP
ON
DIP
1
2
3
4
5
6
7
ON
DIP
1
2
3
4
5
6
7
1
2
3
4
5
6
7
Privacey Switch Blower Switch
NOTE:
The switches on the transmitter and receiver
must match.
Transmitter
Receiver
Privace Dip Switches
(Need to Match)
ST1089
Blower Switch
- Do Not Move
Fig. 32
Privacy switches.