5
RFSDV34 Freestanding Direct Vent Gas Stove
10003550
Testing Remote Control System
1. Light the gas appliance following the lighting instruc-
tions on Page xx. Confirm the pilot light is on; it must
be in operation for the remote control to operate the
main gas valve and blower. Appliance control knob
must be in the ON position, and ON/OFF switch must
be in OFF position.
. Slide the 3 position button on the remote receiver to
the ON position and the main gas flame should ignite.
3. Slide the button to OFF and the main gas flame should
extinguish, but the pilot light will remain lit.
4. Slide the button to RS (the center position). Press the
ON button on transmitter to turn the system ON. The
main gas flame should ignite and blower should come
on after the On delay time is reached and fan speed
you desire is selected.
5. Press the OFF button on transmitter to turn the system
to OFF. The flame should extinguish (the pilot light will
remain lit) and blower should be off after the Off delay
time is you set is reached.
Blower Speed Level Adjustment
1. The three speed levels of blower can be fine tuned by
using the blower switches. (Fig. 43)
. In the event the blower runs too slow or too fast on
Low or Medium, change the blower switch setting to
achieve desired speed levels.
3. Turn on the blower at low speed with the transmit-
ter and start from STEP 1 (ON/ON/OFF), then follow
steps in the chart below to set up the blower switches.
The blower speed will decrease when going through
the steps. Stop when the desired speed level of Low is
achieved.
4. To ensure the proper Low is selected, run through
Low, Medium, High to check all speeds to achieve the
desired best speed levels.
NOTE:
It is very important that the Low speed is not too
low that to overload blower motor.
WARNING:
To avoid overheating the blower when the
blower runs too slow, always start from higher speed
(from Step 1) when adjusting speed levels using the blow-
er switches. And stop trying the rest of the settings when
desired speed level of Low is achieved.
ON
DIP
1
2
3
4
5
6
7
ON
DIP
1
2
3
4
5
6
7
1 2
3 4 5 6 7
Privacey Switch Blower Switch
FP2599
blower switches
DIP 5 DIP 6 DIP 7
STEP 1
ON
ON
OFF
STEP 2
(Default)
ON
ON
ON
STEP 3
OFF
ON
ON
STEP 4
OFF OFF
ON
STEP 5
OFF OFF OFF
Fig. 43
Blower speed level adjustment.
FP599