Dura 65
25 | Page
Version 1.0v-05/2021
© Verder International B.V
7.8 Replace the Gearbox Adaptor/
Bearing Carrier Seal
Death or crushing of limbs caused by falling loads!
u
Use lifting gear appropriate for the total weight to be trans-
ported.
u
Make sure the pump and accessories are lifted and moved
by qualified lifting personnel equipped with suitable lifting
gear.
u
Do not stand under suspended loads.
Risk of injury!
u
Always isolate the power supply before working on the
pump.
Risk of injury while dismounting the pump!
u
Use protective equipment when carrying out any work on
the pump.
Checklist:
[
Motor isolated.
[
System secured against being switched back on again.
1. Remove the hose. Please refer to (→
7.6).
2. Remove the front cover. Use lifting gear for the front cover
to be moved.
3. Fasten the lifting gear to the front cover lifting eye as
shown in the following illustration.
4. Loosen the hex head set screws for the front cover to be
removed.
5. Remove the hex head set screws of the drive coupling.
6. Remove the drive coupling and the O-ring.
Please note that they are different sizes of the drive coupling
depending on the GMU size.
DANGER
WARNING
CAUTION
Figure 27 Remove the Front Cover
7. Remove the motor from the gearbox.
8.
Loosen the hex head screws to remove the gearbox from
the gearbox adaptor.
Figure 28 Remove the Drive Coupling
Figure 29 Remove the Motor
Figure 30 Remove the Gearbox
Note