Dura 65
12 | Page
Version 1.0v-05/2021
© Verder International B.V
5.4 Installing the Motor and Gearbox
(where not supplied)
Death or crushing of limbs caused by falling loads!
u
Use lifting gear appropriate for the total weight to be trans-
ported.
u
Make sure the pump and accessories are lifted and moved
by qualified lifting personnel equipped with suitable lifting
gear.
u
Do not stand under suspended loads.
Please consult the motor and gearbox manual for the orienta
-
tion of gearbox and use of a breather.
1. Attach the key to gearbox shaft.
2. Apply anti seize grease to the gearbox shaft.
3. Attach the gearbox to the pump housing.
4. Fit the screw hex head with washers to fasten the gearbox
to the gearbox adaptor.
Please note that the size and number of the screws depends on
the type of the gearbox as follows:
u
For the 303/304/305 Gearboxes, M12 Screws x10
u
For the 306 Gearbox, M14 Screws x 12
5. Use a torque wrench to apply tightening torque
(
g
Appendix A).
DANGER
6. Apply anti seize grease to the motor shaft.
7. Attach the motor to the gearbox.
Please note that the size and number of the screws depends on
the type of the motor as follows:
u
For the 112/132 Motors, M12 Screws x 4
u
For the 160/180 Motors, M16 Screws x 4
8. Use a torque wrench to apply tightening torque
(
g
Appendix A).
5.4.1 Connecting to Power Supply
Risk to health due to electric shock!
u
All electrical work must be carried out by qualified
electricians.
1. Connect motor to the rated power supply. Ensure the cor-
rect gland is used and that the earth connection is made
and secured.
2. Wiring instructions are available within the motor junction
box.
3. Run the pump slowly to ensure correct rotation.
4. For more information on wiring the motor please refer to
the relevant motor manual.
Figure 5 Installing the Motor
Note
Note
DANGER
Note
Figure 4 Installing the Gearbox