7.4 Drain/Change the Lubricant
Risk of injury!
u
Always isolate the power supply before working on the
pump.
Slip hazard due to spilt lubricant!
u
Care must be taken when lubricant is drained into
a container.
u
Dispose of used lubricant in accordance with local
laws and good environmental practices.
Checklist:
[
Motor isolated.
[
System secured against being switched back on again.
1. Drain the lubricant from the pump housing through drain
port from the back of the pump.
2. Place a suitable container under the drain port.
3. Open the valve and drain the lubricant as shown in the
image.
4. Close the valve in position by rotating the lever to 90° to
the right.
WARNING
Figure 17 Drain the Lubricant
Figure 18 Close the Valve
4. For how to fill the pump housing with lubricant through the
filler port, refer to (→ 5.9 Filling the Pump with Lubricant).
7.5 Grease the Gearbox Adaptor/
Bearing Carrier
Risk of injury due to running pump or hot parts!
u
Do not carry out any repair/maintenance work on a pump
in operation.
u
Allow the pump to cool down completely before starting
any repair work.
1. The grease nipple allows to the lubrication of the main seal
located the gearbox adaptor/bearing carrier.
2. Add 5 grams of grease every 6 months.
Figure 19 Filling the Pump with Lubricant
DANGER
Figure 20 Grease the Gearbox Adaptor/Bearing Carrier
Grease Nipple