5.9 Filling the Pump with Lubricant
Safety data sheets for both Verderlube and Verdersil are
available from the manufacturer for compatibility check.
1. Provide a suitable container to collect spilt lubricant.
2. Ensure compatibility of lubricant with the pumped liquid.
3. The pump housing can be filled with lubricant through the
filler port.
4. Remove the breather cap from the filler port to fill the pump
with lubricant.
5. Fill the pump housing with lubricant at level with the plate
or partly submerge the plate. The indicator plate is visible
through the non-ATEX inspection window.
6. Refer to the Appendix A for the required quantity.
7. Position the breather cap and tighten it firmly.
5.10 Connecting the Pipes
Contamination of pumped media due to impurities in
the pump!
u
Care should be taken to avoid ingress of contaminants
into the pumped media.
[
Clean all piping parts and fittings prior to assembly.
[
Ensure that the flange seal do not protrude inwards
occluding the flow path.
[
Remove flange covers on both the suction and
discharge side prior to installation.
Note
Figure 12 Filling the Pump with Lubricant
Figure 13 Positioning the Breather Cap
Figure 11 Lubricant Level Indicator Plate
Level Indicator
Plate