Table 2
Overall dimensions
The fan has four ventilation modes:
1. Standby mode - standard operation mode for the fan in case of no signalling from the sensors or external switch.
In standby mode the fan does not run.
2. 24 Hours - the fan runs at low speed for minimum round-the-clock ventilation. As temperature set point is crossed, the fan
switches to MAX mode (by default) or to SILENT mode. The fan switches to SILENT mode when the external switch is closed.
3. SILENT - silent operation mode of the fan. This mode is may be activated by the external switch or after corssing the
temperature set point. For temperature sensor, this mode may be activated from the fan.
4. MAX - temperature-activated operation mode. It is switched on as temperature set point is crossed.
This mode is activated for the temperature sensor by default.
4
Speed
Spigot
dia.
Noise level at
3 m [dBA]
Max. air
3
capacity [m /h]
100
24
Hours
33
17
152
206
29 28
100/125
Silent
72
22
Max
106
31
125
24
Hours
40
17
Silent
83
21
Max
133
32
Air capacity,
3
factory settings [m /h]
33
72
82
40
83
97
Air capacity
3
control range [m /h]
-
33 ... 72
72 ... 106
-
40 ... 83
83 ... 133