SILENT MODE SPEED ADJUSTMENT
By default the speed is 83/72 m3/h.
To set the speed:
press the buttons "3CP" and "4CP" on the control panel.
press the buttons "4RC" on the remote controller.
Press the buttons "3CP", "4CP" or "4RC" once to display the
current air capacity.
MAX MODE SPEED ADJUSTMENT
3
By default the speed is 97/82 m /h.
To set the speed:
Press and hold the button "7CP" and then press the buttons
"3CP" and "4CP" on the control panel.
Press the buttons "5RC" on the remote controller.
To display the current air capacity on the control panel,
press and hold the button "7CP" and then press the button "3CP" or "4CP"
once. To display the current air capacity on the remote controller,
press the buttons "5RC".
WARM EXTRACTION MODE SELECTION
By default the Max mode:If the temperature rises above the set point,
the fan switches to higher speed to remove excessive heat.
After the temperature in the room falls 2
°
C below the set temperature point,
the fan switches to the previous mode. To select the warm air extract mode:
Press the button "1CP" on the control panel in cycles.
press the button "2RC" (for Silent) or "3RC" (for Max) on the remote controller.
Max - active hot air response mode with the best impeller performance.
Silent - active warm air response mode with silent operation.
Press the button "1CP" once to display the current mode.
Number of active
light indicators
1
2
3
4
5
6
7
8
9
10
Air capacity
[m3/h]
40
/33
4
4/37
48/41
52/45
57/49
62/53
67/57
72/61
77/66
83/
72
Number of active
light indicators
1
2
3
4
5
6
7
8
9
10
Air capacity
[m3/h]
83/
72
87/75
92/79
97/82
103/86
109/90
1
15/94
1
21/98
12
7/102
133
/106
SILENT MAX