10
Wiring diagram 3
L and N terminals are connected to live and neutral respectively. LT contact is connected to live through external switch,
light switch. The fan is always in standby mode. As 24 HOURS Mode is activated the fan runs permanently at low speed to
ensure minimum round-the-clock ventilation. As the external switch is closed the fan switches to SILENT mode. In some time
after the external switch is closed the fan reverts to the previous mode. If the temperature rises above the set point, the fan is
switched to MAX (by default) or SILENT (if set) mode. After the indoor temperature falls 2
°
C below the set temperature point,
the fan reverts to the previous mode.
L
T
L
N
S
N
L
Standby mode
(fan does not run)
or
24 Hours mode
3
(Fan operates at 40-33 m /h)
Fan operation in
Silent mode
Turn-off delay timer
starts (5-15-30 min)
Switch is
closed
Switch is off
Turn-on delay timer
starts (0-2-5 min)
Switch is off
Temperature
rises
MAX (SILENT)
mode is activated
Temperature falls 2
°
C below
the set temperature point