STORAGE AND TRANSPORTATION RULES 

Transport the product by any transportation vehicle in the manufacturer's original package. 
Store the delivered product in the manufacturer's original packing box in a dry ventilated premise with the temperature range 
from  +5

º

C up to + 40

º

C and relative humidity less than 80%.The storage environment must not contain dust, acid or alkali 

vapours that may cause corrosion of the product parts. 

OPERATION RULES 

The fan is designed for connection to single-phase ac 100-240 V / 50-60 Hz power mains. 
The fan is designed for continuous operation always connected to power mains. 
The fan is rated for operation at the ambient temperature ranging from +1

°

C up to +45

°

C.

The fan is double-insulated and requires no grounding. 
The fan complies with the requirements according to the EU norms and directives, to the relevant EU-Low Voltage Equipment 
Directives, EU-Directives on Electromagnetic Compatibility.

Summary of Contents for iFan Celsius

Page 1: ...NT FAN user s manual model iFan Celsius Approval mark Manufactured on date Sold name and stamp of the trade company Date of sale ACCEPTANCE CERTIFICATE The fan is duly recognized as serviceable F01EN...

Page 2: ...to be used by children and persons with reduced physical mental or sensory capacities without proper practical experience or expertise unless they are controlled or instructed on the product operation...

Page 3: ...125 mm 1 pce 6 Screws and dowels 4 pcs 7 User s manual 1 pce DESCRIPTION Due to constant improvements the design of some models may slightly differ from those ones described in this manual The product...

Page 4: ...d 3 SILENT silent operation mode of the fan This mode is may be activated by the external switch or after corssing the temperature set point For temperature sensor this mode may be activated from the...

Page 5: ...sed to facilitate mounting The fan is equipped with a removable grille Press the latches slightly to release the grille from the front cover While installing the grille on the front cover back match t...

Page 6: ...QF The fan casing has three round lowered tabs for cable entry Cut out a hole at the most suitable place with a knife FAN MOUNTING SEQUENCE 6 4 5 6 1 2 3...

Page 7: ...7 7 8 9 10 11 12...

Page 8: ...e is activated the fan runs permanently at low speed to ensure minimum round the clock ventilation After crossing the temperature set point the fan switches to MAX by default or SILENT mode After the...

Page 9: ...ivated If the temperature rises above the set point the fan is switched to MAX by default or SILENT if set mode After the indoor temperature falls 2 C below the set temperature point the fan reverts t...

Page 10: ...ch is closed the fan reverts to the previous mode If the temperature rises above the set point the fan is switched to MAX by default or SILENT if set mode After the indoor temperature falls 2 C below...

Page 11: ...al momentary switch that is activated by opening a door The fan is in standby mode and does not run As 24 HOURS Mode is activated the fan runs permanently at low speed to ensure minimum round the cloc...

Page 12: ...hot temperature extraction Max mode turn on delay time 0 min off delay time 5 min FAN OPERATION INDICATION The fan is turned on by the external switch the light indicator STATUS is green The fan is i...

Page 13: ...mpagne Silver colours provide high signal conductivity from the remote controller and do not influence the signal transferability The covers of Graphite Violet Topaz or Black Sapphire may suppress the...

Page 14: ...TRACTION MODE SELECTION By default the Max mode If the temperature rises above the set point the fan switches to higher speed to remove excessive heat After the temperature in the room falls 2 C below...

Page 15: ...display the current off delay timer setting TURN ON DELAY TIMER ADJUSTMENT The default time is 0 minutes You can adjust the turn on delay timer to avoid the fan unnecessary switching After signal from...

Page 16: ...ure sensor or external switch is activated The green light indicator under the button 6CP on the control panel is on when 24 Hours mode is activated To activate 24 HOURS mode Press and hold the button...

Page 17: ...n It can not be adjusted or turned off After 15 hours standstill the fan is switched on for 2 hours to ventilate the room with air capacity 83 72 m3 h If the fan receives a signal from the temperature...

Page 18: ...ic clearing of the fan surfaces from dust and dirt To clean the fan use a soft cloth wetted in a water soap solution Wipe the surfaces dry after washing Avoid liquid splashes on the motor and the circ...

Page 19: ...or alkali vapours that may cause corrosion of the product parts OPERATION RULES The fan is designed for connection to single phase ac 100 240 V 50 60 Hz power mains The fan is designed for continuous...

Page 20: ...h the purpose of performing warranty servicing you please produce User Manual or other relevant substituting document and the payment document as an evidence of the purchase with indication of the sal...

Page 21: ...ch seals are prescribed by the User Manual or other relevant substituting document in case of unavailable warranty card in case of unavailable payment document to confirm the purchase with indication...

Page 22: ...22...

Page 23: ...23...

Reviews: