FP15 & FP15A Waterloo - Installation and Operation Manual
WARNING
•
TEMPERED GLASS OR ORDINARY GLASS WILL NOT WITHSTAND THE HIGH TEMPERATURES OF THE
WATERLOO.
•
DO NOT ABUSE THE GLASS DOOR BY SLAMMING IT AGAINST THR FIREPLACE.
•
DO NOT OPERATE THE FIREPLACE WITH A CRACKED OR BROKEN GLASS.
In order to replace the glass, use the following procedure;
1-
Remove the 12 glass retainers
(C)
held in place by 12 screws
(B)
.
2-
Remove the glass
(F)
and/or debris from the frame.
3-
Install the new window into the frame
(G)
and fasten it in place with the glass retainers (C) and the
screws (B) removed earlier.
4-
Handle the glass with care to avoid injury.
5.1.6.1
Replacing the door glass gasket
The gasket must be centred on the edge of the glass. To do this easily, peel back a section of the paper
covering the adhesive and place the gasket on a table with the adhesive side up. Stick the end of the gasket
to the middle of one edge, then press the edge of the glass down onto the gasket, taking care that it is
perfectly centred on the gasket. Peel off more of the backing and rotate the glass and press the next section
onto the gasket. Do not stretch the gasket as you place it. Continue until you get to the start and trim the
gasket to length. Now pinch the gasket to the glass in a U shape, all around the glass. Reinstall the glass,
being careful to centre the glass carefully in the door. Do not over-tighten the screws. Note that the two
main causes of broken door glass are uneven placement in the door and over-tightening of retaining
screws.
Summary of Contents for Waterloo FP15
Page 10: ...10 FP15 FP15A Waterloo Installation and Operation Manual 2 3 Measurements FP15 ...
Page 11: ...FP15 FP15A Waterloo Installation and Operation Manual 11 ...
Page 12: ...12 FP15 FP15A Waterloo Installation and Operation Manual 2 4 Measurements FP15A ...
Page 13: ...FP15 FP15A Waterloo Installation and Operation Manual 13 ...
Page 77: ...FP15 FP15A Waterloo Installation and Operation Manual 77 ...
Page 87: ...NOTES ...
Page 88: ...88 FP15 FP15A Waterloo Installation and Operation Manual ...
Page 89: ......