70
FP15 & FP15A Waterloo - Installation and Operation Manual
Then, install the flexible pipe*
(D)
(not supplied) to the fresh air intake adapter
(B)
using one of the
adjustable pipe clamps
(C)
. Secure the other end of the pipe to the outside wall termination
(E)
using the
second adjustable pipe clamp
(C)
. The outside wall termination
(E)
must be installed outside of the building.
*For a pipe length less than 20 ft, use a 5
″
pipe diameter. For a pipe length of more than 20ft, or having
more than two deviations, use a 6
″
pipe diameter. The maximum pipe length is 30 ft (9 m).
This configuration can be found inside the chase, but must at all times maintain clearances to combustibles.
The following figure is shown as an example.
To complete the installation, make a hole of 1/4" to 1/2" (6 mm à 13 mm) bigger than the insulate pipe
diameter in the outside wall of the house at the chosen location. From outside, place the outside wall
termination in the hole (open side down) and fasten the register to the wall, with screws.
WARNING
TO AVOID CONDENSATION AND RUST IN YOUR FIREPLACE, IT IS RECOMMENDED TO USE AN INSULATED
PIPE LONG ENOUGH (MINIMUM 10FT) AND CONTAINING A "P-TRAP".
Summary of Contents for Waterloo FP15
Page 10: ...10 FP15 FP15A Waterloo Installation and Operation Manual 2 3 Measurements FP15 ...
Page 11: ...FP15 FP15A Waterloo Installation and Operation Manual 11 ...
Page 12: ...12 FP15 FP15A Waterloo Installation and Operation Manual 2 4 Measurements FP15A ...
Page 13: ...FP15 FP15A Waterloo Installation and Operation Manual 13 ...
Page 77: ...FP15 FP15A Waterloo Installation and Operation Manual 77 ...
Page 87: ...NOTES ...
Page 88: ...88 FP15 FP15A Waterloo Installation and Operation Manual ...
Page 89: ......