INSTALLATION GUIDE
REMO
VE OEM DOOR
INS
TALL DOOR
HARNESSING
INS
TALL BUCKET
DROP SENSOR
ADJUS
T DOOR
23
REVISION™ Door for National 157/167 - 158/168
INSTALL DROP SENSOR
Next, position the drop sensor harness and other cables so
they are clear of green LED’s to reduce potential malfunction
when machine is operational.
Then, peel backing from hinge side
Plastic Diverter
(VE9314)
, then mount top plate on drop sensor, attach
diverter to studs, and tighten nuts on studs.
Finally, remove the double-sided tape from the
Magnet
(VE9308A)
and hold in right hand corner of the vend door
until the green LED illuminates. Next, place magnet in iden-
tified location, then move the bucket flap until it touches the
magnet and release the bucket flap.
NOTE:
Check that drop sensor assembly is not tilted or
twisted after mounting.
NOTE:
Move the bucket flap up and down. Green LED on
sensor board should illuminate when the door is 1/2 to 2/3
of the way open, and LED should turn off when delivery
door is 3/4 closed.
7
8
9
THIS SECTION IS COMPLETE,
MOVE ON TO ADJUSTING THE
DOOR
Clear of LED
Green Lit
LED
Plastic
Diverter
Green Lit
LED
Magnet
Position