background image

Cronotermostato

Digitale

Mithos GSM

Manuale d’Uso

User Manual
DIGITAL PROGRAMMABLE THERMOSTAT

Summary of Contents for Mithos GSM

Page 1: ...Cronotermostato Digitale Mithos GSM Manuale d Uso User Manual DIGITAL PROGRAMMABLE THERMOSTAT...

Page 2: ...ock setting Page 9 Programs setting Page 11 Temperatures setting Page 13 Manual operation Page 14 Summer winter operation Page 15 Keypad On Off command Page 16 Timing Page 16 Advanced programming Page...

Page 3: ...in winter and in summer heating air conditioning Integrated GSM module for the remote control of th device throven your mobile Interchangeable silver colored front panel available as accessory code VE...

Page 4: ...s of average temperature of the entire environment Avoid installing too close to doors windows heat sources direct sunlight radiation and positions with excess or total lack of air inlet It is moreove...

Page 5: ...English 4 Mithos GSM Programmable Thermostat User Manual DIMENSIONS CONNECTION DIAGRAM QJUHVVR SHU 7HPS R 20 1 1 1 a 9 a QSXW IRU WHPS RU 20 1 1 1 T3 T2 T1 132 95 36...

Page 6: ...ofrequency signals electromedical devices pacemakers hearing aids etc TECHNICAL CHARACTERISTICS Power supply 230 V AC 15 10 50 60Hz Charge reserve about 1 hour thanks to the backup battery Backup batt...

Page 7: ...nal display in F Automatic change CET DST Password protected keypad lock for installation in public places GSM quad band module 900 950 1800 1900 MHz Integrated gsm antenna Possibility to store up 5 n...

Page 8: ...deactivation of the programmable thermostat 6 Key selects temperature T3 7 Key selects temperature T2 8 Key selects temperature T1 9 Key allows to set a timer or an activation delay 10 Key programs se...

Page 9: ...Environment temperature Field 17 Set program Field 18 Manual operation activation Field 19 Timer Field 20 Air conditioning activation Field 21 Heating activation Field 22 Clock Field 23 Ring or sms r...

Page 10: ...eld 22 will start at 12 00 and will ash until the clock is set Attention if the clock is not set the programmable thermostat will not adjust it will start doing so only once the clock is set CLOCK SET...

Page 11: ...hours is set eld 22 will display a ashing value of the year eld 15 the value of the month and eld 16 the value of the day Press the and keys to modify the values and to con rm Once the day is set pres...

Page 12: ...r If the selected program is correct press the key to continue to the next day If the selected program is not correct for that day you can create another one using the and keys which modify value Px c...

Page 13: ...one hour to the next without modifying the set temperature Pressing the key it is possible to set the activation delay for that speci c hour Each pressure of the key increases the delay by 15 minutes...

Page 14: ...eld 22 to display the writing corresponding to the temperature that is being modi ed on eld 16 the value of the aforementioned temperature will ash With the and keys it is possible to modify the valu...

Page 15: ...anual temperature value will ash With the and keys it is possible to change the value from 2 0 C to 50 C Pressing the key or after 45 seconds from the last operation eld 16 will display the value of t...

Page 16: ...and the symbol or will appear With the and keys it is possible to select one of the two operations The program will go to the desired operation pressing the key or after 45 seconds from the last opera...

Page 17: ...g mode prior to the deactivation press the key again KEYPAD ON OFF COMMAND TIMING The programmable thermostat allows to activate three different timed operation modes useful when you want to maintain...

Page 18: ...will then switch to the one active before deactivation If during timing the system is activated the timing ends In all cases the timing condition is signalled by the symbol Setting a timing Each chang...

Page 19: ...s keypad lock password Field 22 will display the writing rEG and on eld 16 letter O ON OFF programming or P proportional programming will ash system operation hours To enter advanced programming press...

Page 20: ...value The range varies from 0 1 C to 1 C In case of PROPORTIONAL regulation type the parameters to be set are regulation band regulation period Field 22 will display the writing bnd and on eld 16 the...

Page 21: ...lue between 01 0 C and 15 0 C It is also possible to disable the antifreeze function holding the key until eld 16 displays the symbol In this case when the programmable thermostat is off no regulation...

Page 22: ...40 C 60 C Code Model Capacity VN883500 X Temp 40 C 60 C Choosing the regulation probe In case an external probe is present it is possible to choose whether to use the internal probe or the external on...

Page 23: ...sing the and keys choose a desired value and press to con rm To enable disable the keypad lock please refer to the chapter ADVANCED FUNCTIONS System operation hours It is possible to display the syste...

Page 24: ...entral European Time to DST Daylight Saving Time and vice versa Holding the key for at least 3 seconds the display will show the writing Change and eld 15 will ash the writing On or OFF Choose using t...

Page 25: ...e default values set for the automatic time change are winter summer change last Sunday of March at 02 00 summer winter change last Sunday of October at 03 00 Keypad lock In case you want to install t...

Page 26: ...m maximum value memorized press the key for at least 3 seconds Emergency regulation During winter operation in case of sensor failure in order to avoid problems regarding freezing the programmable the...

Page 27: ...the ON or OFF relay within a prede ned regulation cycle on the basis of the gap of the temperature measured by the setpoint value The necessary parameters for the de nition of this mode are the regul...

Page 28: ...emperature T1 T2 T3 Tmanual Tantifreeze switch from the heating mode to the air conditioning mode and vice versa B Information display the temperatures measured by the internal and external probe if e...

Page 29: ...f the symbol indicating the current status For example MITHOS ACCESO MANUALE Inserting the SIM Card In order to remotely control the device with your cell phone a SIM card must be inserted in the spec...

Page 30: ...e GSM signal make a call to Mithos GSM with the number you want to record in the first position of the telephone book The following symbol appears on the display during the call The caller receives a...

Page 31: ...A 1 2221234567 2 VUOTO 3 VUOTO 4 VUOTO 5 3001234567 Ring mode Attention the following procedure is recommended for expert users otherwise use the previously described text message method The GSM funct...

Page 32: ...with the number you want to add to the telephone book The caller will receive a text message from Mithos GSM confirming that the addition was made to exit without recording a new number press the PRG...

Page 33: ...for setting off operation with possible antifreeze MITHOS ACCESO MANUALE for setting manual operation period indicates any timer period values between 0 and 99 unit of measurement indicates the unit o...

Page 34: ...HOS RISCALDAMENTO MITHOS CONDIZIONAMENTO Defining the antifreeze temperature The T0 command can be used to set the antifreeze temperature to be maintained if the programmable thermostat is turned off...

Page 35: ...ed to set the t1 t2 t3 temperatures for the currently set operating mode heating or air conditioning The syntax of the commands to send are T1 tt t sets the T1 temperature of the current operating mod...

Page 36: ...s and current setpoint network power supply status GSM field number of the SIM card inserted in the Mithos GSM date and time With MITHOS INFO information can received regarding the temperature measure...

Page 37: ...r supply alarm if there is a blackout external alarm in the case of a generic alarm on the digital input For each alarm source it is possible to specify the numbers in the telephone book to which the...

Page 38: ...ALLARME ESTERNO 1 3 4 Note newly setting the alarm recipients will overwrite the previous setting therefore all the recipients must be indicated in a single command To delete a setting for the recipi...

Page 39: ...specify the text of the message sent to the numbers in the telephone book following an alarm on the digital input The command syntax is TESTO ALLARME ESTERNO text where text text of maximum 24 charact...

Page 40: ...LARME MINIMA INT 12 2 30 generates a minimum alarm if the temperature measured by the internal probe goes below 12 C for at least 30 minutes and considers the alarm restored when the temperature excee...

Page 41: ...able thermostat for example no or expiring credit By default the unrecognised messages are forwarded to the number in position 1 in the telephone book With the INOLTRA command it is possible to specif...

Page 42: ...rument s GSM parameters specify the number of the inserted SIM card with the command MITHOS NUMERO numero where number is the telephone number of the SIM card inserted in the Mithos GSM The Mithos GSM...

Page 43: ...The backup battery can be accessed by removing the cover and can be replaced without disconnecting the power supply voltage Use NiMh AA batteries with a capacity of 2000 mAh or higher Do not use non r...

Page 44: ...6 17 18 19 20 21 22 23 P3 T3 T2 T1 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 P4 T3 T2 T1 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 P5 T3 T2 T1 0 1 2 3 4 5 6 7 8...

Page 45: ...17 18 19 20 21 22 23 P3 T3 T2 T1 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 P4 T3 T2 T1 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 P5 T3 T2 T1 0 1 2 3 4 5 6 7 8...

Page 46: ...rature value Possible values 2 50 with T1 T2 T3 T2 temperature Sets the temperature T2 of the automatic mode to the temperature value Possible values 2 50 with T1 T2 T3 T3 temperature Sets the tempera...

Page 47: ...rm is sent INVIO ALLARME ALIMENTAZIONE recipient1 recipient5 Indicates the numbers in the telephone book to which the power supply failure or restoration alarm is sent IMPOSTA ALLARME CONTATTO APERTO...

Page 48: ......

Page 49: ...V3ISO0580 011 Vemer S p A I 32032 Feltre BL Via Camp Lonc 16 Tel 39 0439 80638 Fax 39 0439 80619 e mail info vemer it web site www vemer it...

Reviews: