In many cases, the installation site must be inspected by a qualified
electrician for accurate cable section and neck inspection.
Before making any electrical connections, check that no terminals are
powered.
In any doubt, cut off the main electricity from the fuse box.
Using a suitable tool, strip about 5 cm from the outside of the power cable
and about 1 cm from the connecting cables. When doing this, the electrical
cable should not be damaged.
Insert the electric wire through one of the cable entries of the device and
bring the ends to the side of the terminal. Carefully connect the connection
cables to the electrical connection terminals according to the electrical
connection diagram.
Make sure that the screws of the connection terminals are completely
tightened and that they are not under the connecting screws of the cable
insulation. Loose connections may cause the cable to overheat.
The electrical cable must be secured in accordance with TSE standards in
terms of wall location and protection.
The device and its installation must be checked by a qualified electrician at
least every two years due to weaknesses such as in every electric device
that may result in use and aging.
Do not open the device until the front cover is closed.
For safety reasons, the pressure safety switch of the device is positioned
closed at the factory. The pressure safety switch must be turned on before
closing the front cover of the device. Otherwise the device will not be able
to heat up!