Solar Pump Controller Manual
35
H-47
Solar pump running
mode selection
LED 0 digit: Control mode
0: MPPT mode1
1:MPPT mode 2
2.MPPT mode 3
LED 10 digit: Search frequency step
0:Automatic calculate
1:User-defined
LED 100 digit: Dry run protection
0:Invalid
1: Valid
LED 1000 digit: CVT base voltage
adjust
0: Automatic setting
1: Manual
0000
●
32FH
H-48 Frequency step1
0
~
10.00HZ 0.80
●
330H
H-49 Frequency 1
0
~
600.00HZ
25.00
●
331H
H-50 Frequency step2
0
~
10.00HZ 0.30
●
32DH
H-51 Frequency 2
0
~
600.00HZ
32.00
●
32EH
H-52 Frequency step3
0
~
10.00HZ 0.15
●
32FH
H-53 Frequency 3
0
~
600.00HZ
40.00
●
330H
H-54 Frequency step4
0
~
10.00HZ 0.10
●
331H
H-55 Frequency 4
0
~
600.00HZ
45.00
●
332H
H-56 Frequency step 5
0
~
10.00HZ 0.80
●
338H
H-57 Frequency 5
0
~
600.00HZ
48.00
●
339H
H-58 Frequency step 6
0
~
10.00HZ 0.06
●
33AH
H-59
Quick reduce
frequency ratio
0
~
99.99%
96.0
0%
●
33BH
H-60
Long-term stop and
wait time
0
~
6000.0S
900.
0s
●
33CH
H-61
Repeat times in
dormancy
0
~
20 0
●
33DH
H-62 CVT base voltage
0
~
1000
※
●
33BH
H-63 CVT adjust voltage
0
~
100%
80%
●
33BH
H-64
CVT adjust voltage
bias limitation
0
~
10.0%
0.0%
●
33BH
H-65
Dry run protection
limit current
0
~
1000.0A 0.0A
●
33EH
H-66
Linkage main
station setting
0:this machine is linkage slave station
1:main station mode 1
2: main station mode 2
0
●
342H
H-67 Machine
addresses 1
~
247 1
●
343H
Summary of Contents for SI10