Solar Pump Controller Manual
27
F-07
Input signal action
mode selection
LED 0 digit: Free close-down restore
mode
0:After the disconnection, restore the
original order
1:After the disconnection, no restore
the original order
LED 10 digit: Ascend /descent
terminal control frequency setting
0: UP / DW terminals regulate after
running
1: Back to the last shutdown
instantaneous frequency, then UP /
DW regulate
2: First to [F-70], then UP / DW
regulate
LED 100 digit: keyboard
STOP/RESET
Button effective range selection
0: Only keyboard control effective
1: All control mode effective
LED 1000 digit: after fault reset,
terminal operation mode selection
0:Terminal control can restart directly
1: Terminal control ,first close-down
before startup
0001
〇
207H
F-08
Terminal operation
control mode
selection
0:Standard operation control
1:Double-line operation mode control
2:Trilinear operation mode control.
0
〇
208H
F-09
1 step speed
setting 1X
0.00Hz
~
frequency upper limit
20.00
●
209H
F-10
Adjusting
frequency 1 When
ones of H47 value
set for 2
0.00Hz
~
6.00Hz
0.05
●
20AH
F-11
Adjusting
frequency 2 When
ones of H47 value
set for 2
0.00Hz
~
6.00Hz
0.10
●
20BH
F-12
Adjusting
frequency 3 When
ones of H47 value
set for 2
0.00Hz
~
6.00Hz
0.20
●
20CH