Solar Pump Controller Manual
38
H-44
Smallest power change value
can be identified
Range
:
0
~
1000.0w Factory
setting
:
2.0w
These parameters are used to adjust MPPT search effect. Solar pump controller compares output
frequency to get the highest power frequency. Max power search is got by change output frequency.
Max power search begins while output frequency is bigger than the lowest frequency,
increase/decrease frequency according to C-07(search frequency step), calculate output frequency
after sample by H-41(MPPT sample cycle) and compare output between 2 steps, finally get the max
power by adjust the output frequency.
H-45 Pump
power
Range
:
0
~
100.0KW Factory
setting
:※
H-46
Search power change
value
Range
:
0
~
1000W Factory
setting
:
10
MPPT search frequency step is opposite to H-45 and quadratic of output frequency. It is
proportional to H-46. Search frequency step according to different output frequency can be checked
by C-07
H-47
Solar pump running
mode selection
LED 0 digit: Control mode
0: MPPT mode
1:CVT mode
LED 10 digit: Search frequency
step
0:Automatic calculate
1:User-defined
LED 100 digit: Dry run protection
0:Invalid
1: Valid
LED 1000 digit: CVT base voltage
adjust
0: Automatic setting
1: Manual
Factory setting
:
0000
LED 0 digit: Control mode
0: MPPT mode
1: CVT mode
This parameter is set to search max power of the PV panel by different mode while solar pump
control (E-02 set as 10)
LED 10 digit: Search frequency step
0:Automatic calculate: Automatic calculate for search frequency step by H-45,H-46 and output
frequency.
1:User-defined: Set search frequency step by
[H-48~H-58]