OTDR Series
e-Manual, RevE00
Page 102 of 128
8.3.2 OX-MPO-12 Connections/Ports
OX-MPO-12: Example of Connections
The MPO switch is detected automatically when powered on. However, the switch
can be connected at any time; close and re-open the OTDR application and begin
MPO testing.
To connect OTDR to Optical Switch:
1. Use the Micro-USB (B) to Micro-USB (B) cable to connect the switch interface to the OTDR
port.
2. Close and reopen the OTDR application to detect the switch.
3. Attach one end of the 1 m SC-APC to SC-APC simplex patch cord from the OTDR port to
the SC-APC port of the switch.
4. Attach Launch and Receive patchcord cables to the output port of the OX-MPO-12 Switch.
Test Kit Cases to use with the MPO switch are available for purchase from
VeEX.
•
MPO/APC to MPO/UPC hybrid cable to test MPO/UPC FUT (Fiber under
test) and receive cable.
•
MPO/APC on both ends (MPO/APC FUT).
•
MPO/APC to simplex cable fanout 2x (SC-APC, SC-UPC, FC-APC, FC-
UPC, LC-APC, LC-UPC…) to test simplex FUT cable.