Auto Attenuator
: Enable to search all signals. Disable and enter channel for which to search and lock in on.
COM Frequency
:
Get New Sweep Table
: The Sweep Table is used when the Forward or Return Sweep measurement is initiated.
Select this option when moving from one network to another or making significant changes to the Sweep Table. When selected
it clears the existing Sweep Table from the unit's memory.
Then once initiated, the Sweep will not start until a new Sweep Table has been downloaded from the CaLan 3010+.
If this option is not selected, the first time a sweep is performed, the unit cycles through all channels first before generating a
sweep table automatically and saving it in the unit.
CaLan Master Profile
: Select the CaLan 3010H+ Master Profile configured in the Setup screen or using R-Server.
RBW (kHz)
: Select 300 kHz for standard sweep. Select 100 kHz to go deeper with lower Sweep Transmit Levels.
Pilots
: Pilots help determine system levels at each location. Enter the Low/High Pilot channels and frequencies if not using a
CaLan Master Profile.
Low Pilot
: Enter the channel and frequency for the low pass/fail limit.
High Pilot:
Enter the channel and frequency for the high pass/fail limit.
Tap the
ISS
button to view the Pilot Limits for In Service Sweep. Tap
Forward
to return to the Forward Sweep Settings.
In Service Sweep (Pilot Limits)
Spectrum
: Tap to enter the Spectrum Analyzer screen. See
for more information.
Single Ch.
: Tap to see the Single Channel SLM screen. See
for more information.
Tap the
Return
button to view the Return Sweep Settings. See the above descriptions for field details.
CX380C User Manual RevA00