The selected channels for the installation check test need to be active on the selected channel table. The installation check derives
the pass and fail criteria by comparing the measured values to a pre-selected thresholds (locations). If no parameter has been
selected on the active location, a warning message will be displayed.
The following measurements are performed for each analog channel:
Video Power Level in dBmV
Audio1 Power Level in dBmV
V/A1 Ratio in dB
Audio2 Power Level in dBmV
Video/Audio2 Delta in dB
C/N in dB
Max Adjacent Channel Delta in dB
The following measurements are calculated based on the results of all 6 analog channels:
Tilt in dB
Peak-to-Valley in dB
Min Video Level in dBmV
Max Video Level in dBmV
Min Delta V/A1 in dB
Max Delta V/A1 in dB
Min C/N in dB
Max C/N in dB
Max Delta Adjacent Channels in dB