EMR
3
Setup and Operation Manual
Temperature Compensation Delivery Feature
49
Temperature Compensation Delivery Feature
After pressing FINISH following a Temperature Compensated delivery, the operator can toggle the display
between Net Delivered Volume and Gross Delivered Volume by pressing the +/- button. This action toggles the
delivered volume on the display only.
Changing Modes and Presets During Operation
The operator may change modes at any time before and during dispensing by pressing the MODE Button. This
allows the user to change volume presets, currency presets at any time before and during delivery. Rate of flow
may be displayed only during a delivery. Presets and prices that are in the process of being entered are not
recorded until the ENTER button is pressed therefore the preset or price remains intact in the case that the
MODE button was pressed before the entry was completed. The Preset Icon is absent when no preset has been
entered, flashes when preset is disabled, and is solid when enabled.
The following is an example of a delivery that demonstrates this changing of modes and presets. It is not typical
but represents the ability to change the modes and presets.
1. Operator selects the price of $2.00 for the delivery and presses ENTER to accept (no Preset Icon displayed).
2. Presses PRESET button to display the Preset countdown value (No Preset Icon displayed).
3. Presses the NEXT button to set the Currency Preset Of $200.00 and presses ENTER to accept the value
(Preset Icon turns solid).
4. Starts delivery by pressing START Button. If more than one product, select product, then press ENTER.
5. Operator begins dispensing. The Preset Field displays the countdown value of the $200.00 less the currency
value dispensed (Preset Icon remains solid).
6. Presses MODE to go to Volume Mode and presses PRESET button to display the Preset countdown (Preset
Icon remains solid; value displayed will be equal to100 less volume dispensed).
7. Pressing the NEXT button to display current volume preset value (Preset Icon remains solid). The Preset
volume value equivalent displayed will be 100.
8. The Operator changes the Preset value to 200 gallons by entering 200 and pressing ENTER to accept (Preset
Icon remains solid). Display shows the new countdown number of 200 less the amount dispensed.
9. Presses MODE to display currency price ($2.00).
10.Pressing the PRESET button displays the countdown value in currency. The equivalent preset currency value
displayed is $400.00 less value of amount dispensed (The Preset Icon remains solid).
11.Presses MODE button to display a flow rate of in gallons/min. (optional).
12.Presses MODE button to display Volume then PRESET button to display the preset countdown of 200 less
the amount dispensed (Preset Icon remains solid).
13.200 gallons is dispensed and the system stops flow.
14.The
button is pressed to display Preset Disable and then ENTER to disable (Preset Icon begins flashing
and flow is allowed to continue, while recording negative numbers past the preset value).
15.Operator "tops" the tank off at 210 gallons (Preset Icon continues flashing).
16.Presses ENTER (Preset Icon turns solid) and system stops flow. Preset display shows -10 gallons.
17. Presses FINISH to print the ticket (210 gallons @ $2.00 per gallon, $420.00 +taxes = $420.00+ tax).