29
C&C Mode
Initiating the C&C Mode
NOTE: You must first configure the display head for access to C&C Mode as instructed in the EMR
3
Installation
Guide (V-R P/N 577013-758).
1. Press MODE button until the indicator at the bottom of the display points to SETUP.
2. The first C&C Mode category, LANGUAGE, displays in the Descriptor Field. Press NEXT to enter Language
Setup, or continue to press the
button to step through the remaining C&C Mode Setup categories. Press
NEXT to enter any category once it displays in the Descriptor Field.
C&C Mode Setup Categories
•
Language
setup - sets the volume, currency, setup, and printer label descriptions.
•
Display Syntax
setup - sets the punctuation and decimal places for data displayed in the Preset, Register, and
Totalizer Fields.
•
Temperature
setup - sets optional temperature probe’s units to Fahrenheit or Celsius.
•
Fuel Source
setup - sets the meter ID, meter input signal type, and product descriptions.
•
Meter Calibration
setup - sets the calibration of the meter by product using one of three methods.
•
Configure I/O
setup - enables various inputs/outputs such as Emergency Stop and Remote Start & Stop
output.
•
OEM Message
setup - lets you enter the start up OEM message.
•
Delivery Options
setup - lets you enable/disable price changing within the delivery state as allowed by local
regulatory authority, select temperature compensation method, enable delivery timeout, and enable tank ID.
•
Report Formats
setup - lets you print or compose formats for the Delivery Ticket and Shift Report.
•
Restart
setup - allows you to reboot while maintaining current setups, or to reboot and reset all setup selections
to factory default settings as well as removing all current transaction records.
•
Security Code
setup - allows you to enable security code protection to limit access to selected Setup Mode
categories.
Instructions for setting up the C&C Mode setups are shown in the figures that follow. In some cases multiple
figures are used to explain sub-procedures within a C&C Mode category. Once you have entered a C&C Mode
category (pressing NEXT), do not press the
or
buttons in that setup if you do not intend to change a value,
because when you press ENTER, the change, even if unintended, will be accepted. If you want to view setup
settings without making changes, press NEXT to move ‘into’ a category’s setup and ENTER to ‘back out’ of the
setup.
IMPORTANT! If in a C&C Setup you press ENTER too many times, you may ‘back’ out of the C&C Mode and end
up somewhere in the Setup Mode menu. To reenter C&C Mode, follow the button presses in the diagram below:
C&C
LANGUAGE
-
NEXT
Press this key
until you return
to the desired
C&C Setup
category
Press this key
until you see C&C
Setup
Mode
Categories
ENTER SECURITY CODE*
PRICING
TAX/DISCOUNT
DEFAULTS
RELAY CONTROL
SECURITY*
PRINTER OPTION
VIEW RECORDS
RESTORE RECORDS
SHIFT
DATE FORMAT
TIME/DATE
SYSTEM ADDRESS
TIME DELAYS
VERSION NUMBER
C&C
+
* (
Displays if Security is enabled)