background image

  S-19-01-1125-UV101 V1.3 

12 

9. SERVICE AND REPLACEMENT PARTS 

 
For product service please contact your nearest Vector R & D authorized dealer you purchased product. 
Replacement Accessories 
 

Part # 

Description 

Contents 

1125B70  Vector LED-P Wall Plug-In Power Supply 

1x Power Supply 

1125B80  Vector LED-P eye protection shield   

1x Eye Shield 

803 

Sterilizable fiber optic light guide 8 mm diameter 

1x light guide (8 mm) 

1125A19  Vector LED-P Charging Base Assembly 

1x Charging Base 

1125A20  Vector LED-P Handpiece Assembly 

1x Handpiece 

 
Optional accessories 
 

Part # 

Description 

Contents 

LM200 

Digital Light Radiometer 200 

1x Light meter 200 

810 

Sterilizable fiber optic light guide 10mm diameter 

1x 10mm diameter 

809 

Sterilizable fiber optic light guide 8>3mm diameter 

1x 8>3mm diameter 

807 

Sterilizable fiber optic light guide 12>8mm diameter 

1x 12>8mm diameter 

805 

Sterilizable fiber optic light guide 12mm diameter 

1x 12mm diameter 

803 

Sterilizable fiber optic light guide 8mm diameter 

1x 8mm diameter 

 
Note: The handpeice program might crash in some special cases - no response when you 
press buttons on the keypad. You can reset the hanpiece program by poking through the 
cave on the back of handpiece to resume its function when it stops working (See Figure 9.1).   

 

Figure 9 

Summary of Contents for LED-P

Page 1: ...S 19 01 1125 UV101 V1 3 Vector LED Curing Light Vector LED P Instructions For Use VECTOR R D INC 6824 19TH ST 230 UNIVERSITY PLACE WA 98466 USA Website www vectorusa net User Manual...

Page 2: ...e Environment 6 Installation of the unit p 7 6 1 Initial Setup 6 2 Keypad And Modes 6 3 Timer Selection 6 4 Battery Charging 7 Operation Instruction p 10 8 Operating Errors Trouble shooting p 11 9 Ser...

Page 3: ...ON Do not look directly into the light emitted from this curing unit It may be harmful to the eyes Exposure must be restricted to the area of the oral cavity in which clinical treatment is intended Do...

Page 4: ...Check unit for adequate light output before each procedure Failure to verify output may allow inadequate curing 6 In order to avoid electric shock do not introduce any objects into the unit with the...

Page 5: ...t output at about 1 400 mW cm 3 Seconds to cure most resin based composite in the market It also features Digital timer display multiple mode selection boost fast curing and ramp up soft start Two but...

Page 6: ...25 minutes Dimensions Diameter 25 30 mm Length with without light guide 240 mm 180 mm Weight with light guide and battery Roughly 155 g 5 3 Charging Base and Handpiece Time to charge empty battery App...

Page 7: ...take about 6 hours Use only the power supply furnished with the light system Attempting to use another power supply source may cause injury or damage and will void the warranty 3 Mode button surround...

Page 8: ...all local requirements Always use unit in conjunction with a properly grounded outlet 6 2 Keypad and modes There are 2 buttons on the key pad for the mode timer selection and the on off button Fig 5...

Page 9: ...tached to the charging base or attach the power supply directly to the handpiece When this is done the POWER INDICATOR On Off button surrounding will illuminate Figure 7 The light may be used with the...

Page 10: ...the surface being treated Rotate the light guide into the optimal position for polymerization Place the light guide as close to the filling material as possible Avoid directly contacting the filling m...

Page 11: ...when placing handpiece on the charging base Check the power plug connects to power outlet socket firmly If not sure what happen contact the dealer 6 Battery working time is significantly shortened Ba...

Page 12: ...l accessories Part Description Contents LM200 Digital Light Radiometer 200 1x Light meter 200 810 Sterilizable fiber optic light guide 10mm diameter 1x 10mm diameter 809 Sterilizable fiber optic light...

Page 13: ...moved with alcohol a plastic spatula may help in removing the material Do not use any sharp or pointed tools to protect the surface of the light guide from scratching To disinfect place the cleaned li...

Page 14: ...re shield with a soft cloth and if required a mild cleaning agent Solvents or abrasive cleaners may not be used in any case as they damage the plastic components Make sure that charge connector remain...

Page 15: ...t by an authorized engineer dealer warranty will expire immediately 13 3 Warranty Exception The warranty stated herein is the sole warranty applicable to Vector R D products Vector R D expressly discl...

Reviews: