1.5 Specifications V341
1.4 Specifications V1841/V241
NOTE
NOTE
Note 1: The Effective Input Current should be used for the determination of cable size &
Note 1: The Effective Input Current should be used for the determination of cable size &
supply requirements.
supply requirements.
Note 2: Generator Requirements at the Maximum Output Duty Cycle.
Note 2: Generator Requirements at the Maximum Output Duty Cycle.
Note 3: Motor start fuses or thermal circuit breakers are recommended for this application.
Note 3: Motor start fuses or thermal circuit breakers are recommended for this application.
Check local requirements for your situation in this regard.
Check local requirements for your situation in this regard.
Due to variations that can occur in manufactured products, claimed performance, voltages,
Due to variations that can occur in manufactured products, claimed performance, voltages,
ratings, all capacities, measurements, dimensions and weights quoted are approximate
ratings, all capacities, measurements, dimensions and weights quoted are approximate
only. Achievable capacities and ratings in use and operation will depend upon correct
only. Achievable capacities and ratings in use and operation will depend upon correct
installation, use, applications, maintenance and service.
installation, use, applications, maintenance and service.
IP23
IP23
Description
Description
Weight
Weight
Power Source Dimensions
Power Source Dimensions
Cooling
Cooling
Welder Type
Welder Type
European Standards
European Standards
Number of Phases
Number of Phases
Nominal Supply Voltage
Nominal Supply Voltage
Nominal Supply Frequency
Nominal Supply Frequency
Welding Current Range
(DC STICK Mode)
Welding Current Range
(DC STICK Mode)
Welding Current Range
(DC TIG Mode)
Welding Current Range
(DC TIG Mode)
Single Phase Generator
Requirement
Single Phase Generator
Requirement
STICK (MMA)
Welding Output, 40ºC, 10 min.
STICK (MMA)
Welding Output, 40ºC, 10 min.
TIG (GTAW)
Welding Output, 40ºC, 10 min.
TIG (GTAW)
Welding Output, 40ºC, 10 min.
Open circuit voltage
Open circuit voltage
Protection Class
Protection Class
Maximum Input Current
Maximum Input Current
Effective Input Current
Effective Input Current
VECTOR DIGITAL V241 AC/DC
21.9 kg
H525mmxW260mmxD445mm
Fan Cooled
Inverter Power Source
EN 60974-1 / IEC 60974-1
1
230V +/- 15%
50/60Hz
10 - 200A
10 - 200A
29.5A
41.7A
14.4kVA
200A @ 50%, 28V
141A @ 100%, 25.6V
200A @ 50%, 18V
141A @ 100%, 15.6V
66V DC
IP23
VECTOR DIGITAL V341 AC/DC
VECTOR DIGITAL V1841 AC/DC
26.4 kg
10
.
9 kg
Fan Cooled
Fan Cooled
Inverter Power Source
Inverter Power Source
EN 60974-1 / IEC 60974-1
EN 60974-1 / IEC 60974-1
3
1
400V +/- 15%
230V +/- 15%
50/60Hz
50/60Hz
30 - 300A
10 - 170A
10 - 300A
10 - 180A
12.4A
20A
17.5A
33.9A
18.2KVA
11.7KVA
300A @ 50%, 32.0V
212A @ 100%, 28.5V
170A @ 35%, 26
.
8V
100A @ 100%, 24V
300A @ 50%, 22.0V
212A @ 100%, 18.5V
180A @ 35%, 17
.
2V
107A @ 100%, 14
.
3V
66V DC
66V DC
H525mmxW260mmxD445mm
H395mmxW180mmxD375mm