INSTALLATION
Series 613
64/149
Edition 12.08.2022
984360EC
Interface
Set
Resp
Get
Resp
Data
Set, Get Resp
Description
s:20
s:20
i:20
i:20 abcdefgh
Setup1
a Baud Rate:
0=600,1=1200,2=2400,3=4800,4=9600,5=19200,6=38400,7=57600,8=115200,9=230400
b Parity Bit:
0=Even, 1=Odd, 2=Mark, 3=Space
c Data Length:
0=7bit, 1=8bit
d Stop Bit:
0=1bit, 1=2bit
e Command Set:
0=IC, 1=PM
f Digital Input 1:
0=Interlock Open, 1=Interlock Open Inverted, 2=Disabled
g Digital Input 2:
0=Interlock Close, 1=Interlock Close Inverted, 2=Disabled
h Second Answer (PM Command Set):
0=disabled, 1=enabled
s:21
s:21
i:21
i:21 abbbbbb
Setup2
a Position Range:
0=1000, 1=10000, 2=100000
b Pressure Range:
1000 .. 100000
s:22
s:22
i:22
i:22 abbbcdee
Setup3
a Operation Mode:
0=RS232, 1=RS485, 2=RS485 Peer to Peer
b Device Address:
0 … 999
c Duplex Mode:
0=Full, 1=Half
d Termination:
0=LF (CR/LF), 1=CR
e Reserved