INSTALLATION
Series 613
38/149
Edition 12.08.2022
984360EC
5.11.3
Cycle Counter
5.11.3.1
Control Cycle
A control cycle is a complete movement of the valve, from closing to opening and back to closing, or in
percentage of movement it is 200%. Each movement is added up until 200% of the movement is reached,
and then the cycle counter is incremented by 1.
Location: CPA/Parameters: Valve.Position Cycle Counter
Parameter
Description
Control Cycles
The value is writable to be able to reset it
Control Cycles Total
Non-resettable value
5.11.3.2
Isolation Cycle
Counts each compression of the O-ring during the closing process
(Each transition of Isolation State from ‘Not Isolated’ to ‘Isolated’)
Location: CPA/Parameters: Valve.Position Cycle Counter
Parameter
Description
Isolation Cycles
The value is writable to be able to reset it
Isolation Cycles Total
Non-resettable value
5.11.4
Position Restriction
This allows the position of the valve to be limited in open direction.
The limitation is effective in any control mode
If restriction is active:
Position State remains in Intermediate
Digital outputs Open becomes not active
Location: CPA/Parameters: Valve.Position Restriction
Parameter
Description
Enable
Enable the restriction
Maximum Position
High position limit
Restriction Active
Indicates that the position is currently restricted by the Position Restriction.