OPERATION
Series 613
116/149
Edition 12.08.2022
984360EC
6.3.7
Automated Controller Selector
With the 4 Controllers it is possible to define different pressure control settings.
The Automated Controller Selector can select one of the 4 Controllers depending on Target Pressure (Mode:
Threshold
) or Up-Down Control (Mode:
Pressure Direction
)
Mode:
Threshold
Threshold Condition:
Lower or Equal
Threshold Condition:
Equal
Controller Selector changes when the Target Pressure
exceeds or falls below a Threshold value
Controller Selector changes only when the Target Pressure
is equal to a Threshold value
Mode:
Pressure Direction
Controller Pressure Rising:
Controller 1
Controller Pressure Falling:
Controller 2
Controller Selector changes depending on whether Target Pressure is rising or falling