![VAT 613 Series Installation, Operating, & Maintenance Instructions Download Page 124](http://html1.mh-extra.com/html/vat/613-series/613-series_installation-operating-and-maintenance-instructions_4067198124.webp)
TROUBLE SHOOTING
Series 613
124/149
Edition 12.08.2022
984360EC
Code Description
Solution
30
SFV: Motion controller failure in master-slave
communication
Contact vat support
40
Compressed air error
Check compressed air
42
Power supply, low voltage detected
Check if power supply is ok and is able to deliver needed
power
96
SFV: Position deviation axis1 to axis2 at
homing procedure
•
1)
•
O-ring sticking
97
SFV: Position deviation axis1 to axis2 at
operating
1)
98
Position error during closing procedure
1)
99
Position error at operating
1)
200
Valve configuration error, not possible to
operate the valve with these configuration
Contact VAT support
701
Wrong ident code axis 1
Check wiring
702
Wrong ident code axis 2
703
Wrong ident code axis 2 AND axis 1
704
Wrong ident code axis 3
705
Wrong ident code axis 3 AND axis 1
706
Wrong ident code axis 3 AND axis 2
707
Wrong ident code axis 3 AND axis 2 AND axis 1
707
Do not operating mode active