Revision: 2
Date: 11-15-19
VASHON AIRCRAFT RANGER R7 MAINTENANCE MANUAL
A-15
Operational/Functional Inspection Report
Initials
Notes
1
Flight Controls:
-
Check that controls operate in the correct direction
-
Ensure movement through full range of travel
without binding and that there is no excessive
friction
2
Engine Controls:
-
Ensure movement through full range of travel
without binding
3
Battery Master Switch:
-
Switch on
-
Verify voltage indication on EFIS
4
Flaps:
-
Check that flaps go from zero to 20° position with
first push of switch “DN”, verify position indication on
EFIS
-
Check that flaps go from 20° position to 40° with
sec
ond push of switch “DN”, verify position
indication on EFIS
-
Check that flaps go from 40° to 20° with first push of
switch “UP”
-
Check that flaps go from 20° to 0° with first push of
switch “UP”
-
Ensure operation through full range of travel without
binding
Note: some aircraft may be configured differently.
5
Elevator Trim:
-
Ensure operation through full range of travel without
binding
-
Verify proper position indication on EFIS
6
Altimeter:
-
Must indicate within 50 feet of field elevation when
set to correct barometric pressure
7
Start engine using procedure in Pilot’s Operating
Handbook, Section 4
8
Set 1700 RPM:
-
Perform magneto check
-
Drop not to exceed 150 RPM or 75 RPM differential
between magnetos
-
No engine roughness
9
Apply Carburetor Heat:
-
Verify slight drop in engine RPM
-
Verify increase in carb temp