Servicing
108
If all points are complied with:
Lift the hood over the mounting plate
at an angle of 45°.
Carefully lower the hood until the rear
is engaged at the mounting plate.
Connect the PE conductor between
the hood and battery inverter.
Check the electrical connection
between hood and central earthing
point by continuity testing.
Swivel the hood to the device.
Observe the position of the
ON/OFF switch.
Make sure that no lines are
jammed!
The spring must click into place!
Close the energy storage system with
the three included screws at the
bottom.
Checking the PE connection